<?xml version="1.0" encoding="UTF-8"?>
<EXPERIMENT_SET xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <EXPERIMENT alias="GSM2265624" accession="SRX2009495">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009495</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265624</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265624: SF8628_H3K27M_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607527">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607527</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265624</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265624</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265624</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265625" accession="SRX2009496">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009496</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265625</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265625: SF8628_H3K27M_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607528">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607528</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265625</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265625</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265625</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265626" accession="SRX2009497">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009497</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265626</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265626: SF8628_Rna_Pol_II_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607529">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607529</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265626</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265626</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265626</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265627" accession="SRX2009498">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009498</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265627</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265627: SF8628_Rna_Pol_II_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607530">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607530</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265627</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265627</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265627</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265628" accession="SRX2009499">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009499</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265628</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265628: SF8628_H3K27ac_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607531">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607531</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265628</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265628</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265628</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265629" accession="SRX2009500">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009500</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265629</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265629: SF8628_H3K27ac_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607532">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607532</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265629</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265629</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265629</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265630" accession="SRX2009501">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009501</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265630</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265630: SF8628_SUZ12_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607533">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607533</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265630</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265630</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265630</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265631" accession="SRX2009502">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009502</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265631</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265631: SF8628_SUZ12_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607534">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607534</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265631</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265631</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265631</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265632" accession="SRX2009503">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009503</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265632</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265632: SF8628_EZH2_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607535">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607535</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265632</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265632</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265632</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265633" accession="SRX2009504">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009504</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265633</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265633: SF8628_EZH2_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607536">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607536</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265633</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265633</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265633</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265634" accession="SRX2009505">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009505</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265634</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265634: SF8628_H3K27me3_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607537">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607537</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265634</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265634</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265634</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265635" accession="SRX2009506">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009506</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265635</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265635: SF8628_H3K27me3_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607538">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607538</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265635</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265635</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265635</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265636" accession="SRX2009507">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009507</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265636</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265636: SF8628_BRD2_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607539">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607539</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265636</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265636</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265636</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265637" accession="SRX2009508">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009508</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265637</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265637: SF8628_BRD2_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607540">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607540</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265637</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265637</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265637</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265638" accession="SRX2009509">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009509</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265638</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265638: SF8628_BRD4_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607541">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607541</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265638</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265638</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265638</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265639" accession="SRX2009510">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009510</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265639</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265639: SF8628_BRD4_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607542">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607542</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265639</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265639</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265639</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265640" accession="SRX2009511">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009511</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265640</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265640: SF8628_H3.3_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607543">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607543</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265640</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265640</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265640</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265641" accession="SRX2009512">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009512</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265641</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265641: SF8628_H3.3_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607544">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607544</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265641</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265641</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265641</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265642" accession="SRX2009513">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009513</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265642</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265642: SF8628_H3K4me1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607545">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607545</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265642</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265642</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265642</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265643" accession="SRX2009514">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009514</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265643</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265643: SF8628_input_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607546">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607546</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265643</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265643</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265643</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265644" accession="SRX2009515">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009515</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265644</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265644: SF8628_input_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607547">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607547</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265644</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265644</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265644</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265645" accession="SRX2009516">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009516</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265645</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265645: SU_DIPG_IV_H3K27M_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607548">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607548</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265645</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265645</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265645</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265646" accession="SRX2009517">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009517</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265646</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265646: SU_DIPG_IV_H3K27M_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607549">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607549</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265646</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265646</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265646</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265647" accession="SRX2009518">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009518</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265647</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265647: SU_DIPG_IV_BRD2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607550">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607550</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265647</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265647</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265647</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265648" accession="SRX2009519">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009519</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265648</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265648: SU_DIPG_IV_BRD4; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607551">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607551</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265648</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265648</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265648</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265649" accession="SRX2009520">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009520</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265649</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265649: SU_DIPG_IV_H3K27ac_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607552">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607552</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265649</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265649</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265649</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265650" accession="SRX2009521">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009521</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265650</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265650: SU_DIPG_IV_H3K27ac_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607553">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607553</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265650</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265650</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265650</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265651" accession="SRX2009522">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009522</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265651</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265651: SU_DIPG_IV_H3.3; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607554">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607554</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265651</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265651</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265651</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265652" accession="SRX2009523">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009523</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265652</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265652: SU_DIPG_IV_SUZ12_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607555">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607555</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265652</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265652</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265652</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265653" accession="SRX2009524">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009524</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265653</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265653: SU_DIPG_IV_SUZ12_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607556">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607556</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265653</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265653</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265653</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265654" accession="SRX2009525">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009525</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265654</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265654: SU_DIPG_IV_EZH2_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607557">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607557</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265654</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265654</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265654</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265655" accession="SRX2009526">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009526</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265655</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265655: SU_DIPG_IV_EZH2_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607558">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607558</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265655</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265655</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265655</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265656" accession="SRX2009527">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009527</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265656</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265656: SU_DIPG_IV_K27me3_rep1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607559">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607559</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265656</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265656</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265656</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265657" accession="SRX2009528">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009528</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265657</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265657: SU_DIPG_IV_K27me3_rep2; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607560">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607560</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265657</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265657</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265657</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265658" accession="SRX2009529">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009529</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265658</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265658: SU_DIPG_IV_Rna_Pol_II; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607561">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607561</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265658</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265658</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265658</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265659" accession="SRX2009530">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009530</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265659</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265659: SU_DIPG_IV_H3K4me1; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607562">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607562</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265659</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265659</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265659</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265660" accession="SRX2009531">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009531</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265660</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265660: SU_DIPG_IV_input; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607563">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607563</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265660</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265660</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265660</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265661" accession="SRX2009532">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009532</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265661</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265661: SF7761_H3K27M; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607564">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607564</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265661</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265661</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265661</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265662" accession="SRX2009533">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009533</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265662</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265662: SF7761_H3K27ac; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607565">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607565</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265662</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265662</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265662</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265663" accession="SRX2009534">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009534</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265663</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265663: SF7761_H3.3; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607566">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607566</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265663</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265663</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265663</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265664" accession="SRX2009535">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009535</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265664</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265664: H3.3_NEG_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607567">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607567</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265664</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265664</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265664</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265665" accession="SRX2009536">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009536</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265665</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265665: H3K27M_NEG_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607568">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607568</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265665</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265665</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265665</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265666" accession="SRX2009537">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009537</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265666</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265666: input_NEG_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607569">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607569</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265666</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265666</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265666</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265667" accession="SRX2009538">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009538</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265667</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265667: H3.3_POS_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607570">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607570</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265667</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265667</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265667</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265668" accession="SRX2009539">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009539</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265668</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265668: H3K27M_POS_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607571">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607571</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265668</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265668</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265668</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265669" accession="SRX2009540">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009540</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265669</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265669: input_POS_CTRL; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607572">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607572</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265669</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265669</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265669</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265670" accession="SRX2009541">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009541</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265670</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265670: HCT_H3wt_H3K27ac; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607573">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607573</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265670</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265670</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265670</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265671" accession="SRX2009542">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009542</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265671</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265671: HCT_H3K27M_doxy_pos_H3K27ac; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607574">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607574</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265671</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265671</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265671</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265672" accession="SRX2009543">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009543</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265672</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265672: HCT_H3K27M_doxy_withdrawn_H3K27ac; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607575">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607575</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265672</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265672</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265672</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265673" accession="SRX2009544">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009544</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265673</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265673: HCT_H3K27M_doxy_pos_H3K27M; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607576">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607576</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265673</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265673</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265673</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265674" accession="SRX2009545">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009545</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265674</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265674: HCT_H3K27M_doxy_withdrawn_H3K27M; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607577">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607577</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265674</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265674</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265674</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265675" accession="SRX2009546">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009546</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265675</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265675: HCT_input; Homo sapiens; ChIP-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607578">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607578</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265675</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>ChIP-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>GENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>ChIP</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265675</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265675</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265676" accession="SRX2009547">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009547</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265676</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265676: SF8628_DMSO_300nM_3h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607579">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607579</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265676</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265676</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265676</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265677" accession="SRX2009548">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009548</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265677</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265677: SF8628_ DMSO_300nM_6h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607580">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607580</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265677</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265677</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265677</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265678" accession="SRX2009549">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009549</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265678</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265678: SF8628_DMSO_300nM_12h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607581">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607581</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265678</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265678</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265678</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265679" accession="SRX2009550">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009550</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265679</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265679: SF8628_DMSO_300nM_24h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607582">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607582</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265679</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265679</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265679</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265680" accession="SRX2009551">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009551</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265680</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265680: SF8628_DMSO_300nM_48h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607583">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607583</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265680</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265680</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265680</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265681" accession="SRX2009552">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009552</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265681</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265681: SF8628_DMSO_300nM_3h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607584">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607584</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265681</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265681</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265681</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265682" accession="SRX2009553">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009553</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265682</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265682: SF8628_ DMSO_300nM_6h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607585">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607585</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265682</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265682</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265682</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265683" accession="SRX2009554">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009554</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265683</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265683: SF8628_DMSO_300nM_12h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607586">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607586</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265683</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265683</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265683</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265684" accession="SRX2009555">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009555</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265684</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265684: SF8628_DMSO_300nM_24h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607587">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607587</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265684</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265684</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265684</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265685" accession="SRX2009556">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009556</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265685</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265685: SF8628_DMSO_300nM_48h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607588">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607588</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265685</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265685</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265685</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265686" accession="SRX2009557">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009557</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265686</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265686: SF8628_JQ1_300nM_3h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607589">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607589</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265686</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265686</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265686</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265687" accession="SRX2009558">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009558</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265687</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265687: SF8628_ JQ1_300nM_6h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607590">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607590</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265687</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265687</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265687</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265688" accession="SRX2009559">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009559</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265688</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265688: SF8628_JQ1_300nM_12h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607591">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607591</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265688</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265688</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265688</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265689" accession="SRX2009560">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009560</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265689</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265689: SF8628_JQ1_300nM_24h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607592">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607592</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265689</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265689</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265689</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265690" accession="SRX2009561">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009561</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265690</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265690: SF8628_JQ1_300nM_48h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607593">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607593</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265690</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265690</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265690</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265691" accession="SRX2009562">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009562</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265691</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265691: SF8628_JQ1_300nM_3h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607594">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607594</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265691</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265691</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265691</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265692" accession="SRX2009563">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009563</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265692</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265692: SF8628_ JQ1_300nM_6h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607595">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607595</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265692</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265692</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265692</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265693" accession="SRX2009564">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009564</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265693</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265693: SF8628_JQ1_300nM_12h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607596">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607596</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265693</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265693</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265693</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265694" accession="SRX2009565">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009565</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265694</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265694: SF8628_JQ1_300nM_24h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607597">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607597</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265694</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265694</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265694</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265695" accession="SRX2009566">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009566</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265695</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265695: SF8628_JQ1_300nM_48h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607598">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607598</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265695</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265695</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265695</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265696" accession="SRX2009567">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009567</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265696</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265696: SU_DIPG_IV_DMSO_300nM_3h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607599">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607599</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265696</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265696</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265696</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265697" accession="SRX2009568">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009568</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265697</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265697: SU_DIPG_IV_ DMSO_300nM_6h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607600">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607600</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265697</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265697</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265697</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265698" accession="SRX2009569">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009569</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265698</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265698: SU_DIPG_IV_DMSO_300nM_12h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607601">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607601</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265698</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265698</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265698</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265699" accession="SRX2009570">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009570</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265699</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265699: SU_DIPG_IV_DMSO_300nM_24h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607603">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607603</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265699</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265699</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265699</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265700" accession="SRX2009571">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009571</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265700</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265700: SU_DIPG_IV_DMSO_300nM_48h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607602">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607602</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265700</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265700</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265700</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265701" accession="SRX2009572">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009572</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265701</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265701: SU_DIPG_IV_DMSO_300nM_3h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607604">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607604</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265701</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265701</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265701</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265702" accession="SRX2009573">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009573</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265702</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265702: SU_DIPG_IV_ DMSO_300nM_6h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607605">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607605</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265702</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265702</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265702</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265703" accession="SRX2009574">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009574</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265703</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265703: SU_DIPG_IV_DMSO_300nM_12h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607606">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607606</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265703</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265703</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265703</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265704" accession="SRX2009575">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009575</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265704</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265704: SU_DIPG_IV_DMSO_300nM_24h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607607">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607607</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265704</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265704</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265704</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265705" accession="SRX2009576">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009576</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265705</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265705: SU_DIPG_IV_DMSO_300nM_48h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607608">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607608</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265705</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265705</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265705</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265706" accession="SRX2009577">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009577</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265706</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265706: SU_DIPG_IV_JQ1_300nM_3h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607609">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607609</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265706</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265706</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265706</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265707" accession="SRX2009578">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009578</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265707</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265707: SU_DIPG_IV_ JQ1_300nM_6h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607610">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607610</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265707</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265707</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265707</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265708" accession="SRX2009579">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009579</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265708</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265708: SU_DIPG_IV_JQ1_300nM_12h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607611">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607611</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265708</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265708</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265708</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265709" accession="SRX2009580">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009580</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265709</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265709: SU_DIPG_IV_JQ1_300nM_24h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607612">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607612</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265709</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265709</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265709</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265710" accession="SRX2009581">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009581</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265710</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265710: SU_DIPG_IV_JQ1_300nM_48h_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607616">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607616</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265710</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265710</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265710</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265711" accession="SRX2009582">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009582</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265711</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265711: SU_DIPG_IV_JQ1_300nM_3h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607613">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607613</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265711</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265711</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265711</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265712" accession="SRX2009583">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009583</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265712</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265712: SU_DIPG_IV_ JQ1_300nM_6h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607614">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607614</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265712</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265712</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265712</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265713" accession="SRX2009584">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009584</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265713</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265713: SU_DIPG_IV_JQ1_300nM_12h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607615">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607615</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265713</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265713</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265713</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265714" accession="SRX2009585">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009585</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265714</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265714: SU_DIPG_IV_JQ1_300nM_24h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607618">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607618</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265714</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265714</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265714</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265715" accession="SRX2009586">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009586</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265715</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265715: SU_DIPG_IV_JQ1_300nM_48h_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607617">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607617</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265715</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265715</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265715</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265716" accession="SRX2009587">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009587</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265716</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265716: SF8628_CTRL_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607619">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607619</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265716</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265716</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265716</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265717" accession="SRX2009588">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009588</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265717</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265717: SF8628_CTRL_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607620">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607620</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265717</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265717</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265717</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265718" accession="SRX2009589">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009589</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265718</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265718: SF8628_shSUZ12_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607623">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607623</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265718</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265718</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265718</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265719" accession="SRX2009590">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009590</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265719</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265719: SF8628_shSUZ12_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607622">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607622</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265719</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265719</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265719</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265720" accession="SRX2009591">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009591</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265720</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265720: DUIV_CTRL_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607621">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607621</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265720</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265720</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265720</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265721" accession="SRX2009592">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009592</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265721</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265721: DUIV_CTRL_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607624">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607624</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265721</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265721</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265721</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265722" accession="SRX2009593">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009593</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265722</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265722: DUIV_shSUZ12_rep1; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607625">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607625</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265722</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265722</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265722</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2265723" accession="SRX2009594">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX2009594</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2265723</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2265723: DUIV_shSUZ12_rep2; Homo sapiens; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP071040" refname="GSE78801">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP071040</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1607626">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1607626</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2265723</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>RNA was extracted using QIAGEN RNeasy kit. DNA after ChIP protocol was isolated using QIAGEN PCR purification kit. ChIP-sequencing libraries were prepared using the KAPA HTP Library Preparation Kit complemented with NEXTflex DNA Barcodes from Bioo Scientific. 10 ng of DNA was used as starting material for input and ip samples. Libraries were amplified using 13 cycles on the thermocycler. Post amplification libraries were size selected at 250- 450bp in length using Agencourt AMPure XP beads from Beckman Coulter. Libraries were validated using the Agilent High Sensitivity DNA Kit. RNA-sequencing  libraries were prepared using the Illumina TruSeq Stranded Total RNA Preparation Kit with  Ribo-Depletion. Input RNA quality was validated using the Agilent RNA 6000 Nano Kit. 200ng-1 µg  of total RNA was used as starting material. Libraries were validated using the Agilent DNA  1000 Kit</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302265723</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2265723</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
</EXPERIMENT_SET>
