<?xml version="1.0" encoding="UTF-8"?>
<EXPERIMENT_SET xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <EXPERIMENT alias="GSM2186423" accession="SRX1817750">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817750</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186423</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186423: WT Germ-free 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480487">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480487</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186423</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186423</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186423</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186424" accession="SRX1817751">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817751</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186424</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186424: WT Germ-free 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480488">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480488</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186424</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186424</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186424</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186425" accession="SRX1817752">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817752</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186425</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186425: WT Germ-free 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480490">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480490</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186425</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186425</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186425</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186426" accession="SRX1817753">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817753</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186426</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186426: WT CONVD 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480489">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480489</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186426</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186426</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186426</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186427" accession="SRX1817754">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817754</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186427</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186427: WT CONVD 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480491">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480491</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186427</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186427</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186427</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186428" accession="SRX1817755">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817755</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186428</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186428: WT CONVD 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480492">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480492</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186428</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186428</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186428</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186429" accession="SRX1817756">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817756</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186429</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186429: WT Exi 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480493">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480493</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186429</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186429</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186429</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186430" accession="SRX1817757">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817757</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186430</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186430: WT Exi 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480494">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480494</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186430</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186430</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186430</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186431" accession="SRX1817758">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817758</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186431</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186431: WT Exi 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480495">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480495</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186431</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186431</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186431</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186432" accession="SRX1817759">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817759</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186432</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186432: WT Chrys 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480496">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480496</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186432</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186432</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186432</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186433" accession="SRX1817760">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817760</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186433</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186433: WT Chrys 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480498">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480498</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186433</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186433</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186433</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186434" accession="SRX1817761">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817761</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186434</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186434: WT Chrys 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480497">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480497</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186434</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186434</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186434</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186435" accession="SRX1817762">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817762</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186435</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186435: Myd88-/- Germ-free 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480499">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480499</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186435</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186435</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186435</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186436" accession="SRX1817763">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817763</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186436</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186436: Myd88-/- Germ-free 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480500">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480500</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186436</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186436</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186436</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186437" accession="SRX1817764">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817764</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186437</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186437: Myd88-/- Germ-free 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480501">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480501</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186437</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186437</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186437</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186438" accession="SRX1817765">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817765</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186438</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186438: Myd88-/- CONVD 1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480502">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480502</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186438</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186438</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186438</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186439" accession="SRX1817766">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817766</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186439</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186439: Myd88-/- CONVD 2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480503">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480503</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186439</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186439</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186439</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM2186440" accession="SRX1817767">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX1817767</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM2186440</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM2186440: Myd88-/- CONVD 3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP076050" refname="GSE82200">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP076050</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS1480504">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS1480504</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM2186440</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>15 larvae were pooled together, snap frozen in liquid nitrogen and stored at -80º C until extraction. Total RNA was extracted by trizol method (Invitrogen), according to the manufacturer’s protocol. Each sample was further cleaned up on RNeasy mini spin column (Quiagen) according to the supplier’s protocol. RNA integrity was assessed by bioanalyzer (Aglient); all samples were found to have a RIN ≥ 9. A total of 3 μg of RNA was used to make RNAseq libraries using the Illumina TruSeq RNA Sample Preparation Kit v2 (Illumina Inc., San Diego, USA). Two minor modifications were made to the protocol provided by the manufacturer. In the step describing the adapter ligation, 1 μl instead of 2.5 μl adaptor was used. In the library size selection step, the library fragments were isolated with a double Ampure XP purification with a 0.7× beads to library ratio. The resulting mRNAseq library was sequenced using an Illumina HiSeq2500 instrument in accordance with the descriptions provided by the manufacturer, with a read length of 1×50 nucleotides. Image analysis and base calling were done by the Illumina HCS version 1.15.1.</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina HiSeq 2500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>302186440</ID>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM2186440</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
</EXPERIMENT_SET>
