<?xml version="1.0" encoding="UTF-8"?>
<EXPERIMENT_SET xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <EXPERIMENT alias="GSM3147994" accession="SRX4106281">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106281</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147994</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147994: CTRL rep1; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322074">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322074</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147994</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147994</ID>
          <LABEL>GSM3147994</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147994</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3147995" accession="SRX4106282">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106282</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147995</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147995: CTRL rep2; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322075">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322075</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147995</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147995</ID>
          <LABEL>GSM3147995</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147995</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3147996" accession="SRX4106283">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106283</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147996</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147996: CTRL rep3; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322076">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322076</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147996</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147996</ID>
          <LABEL>GSM3147996</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147996</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3147997" accession="SRX4106284">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106284</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147997</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147997: CTRL rep4; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322077">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322077</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147997</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147997</ID>
          <LABEL>GSM3147997</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147997</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3147998" accession="SRX4106285">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106285</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147998</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147998: CTRL rep5; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322078">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322078</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147998</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147998</ID>
          <LABEL>GSM3147998</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147998</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3147999" accession="SRX4106286">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106286</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3147999</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3147999: CTRL rep6; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322080">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322080</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3147999</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303147999</ID>
          <LABEL>GSM3147999</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3147999</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148000" accession="SRX4106287">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106287</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148000</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148000: CTRL rep7; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322079">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322079</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148000</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148000</ID>
          <LABEL>GSM3148000</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148000</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148001" accession="SRX4106288">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106288</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148001</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148001: EARLY STAGE rep1; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322081">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322081</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148001</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148001</ID>
          <LABEL>GSM3148001</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148001</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148002" accession="SRX4106289">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106289</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148002</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148002: EARLY STAGE rep2; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322082">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322082</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148002</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148002</ID>
          <LABEL>GSM3148002</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148002</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148003" accession="SRX4106290">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106290</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148003</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148003: EARLY STAGE rep3; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322083">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322083</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148003</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148003</ID>
          <LABEL>GSM3148003</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148003</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148004" accession="SRX4106291">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106291</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148004</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148004: EARLY STAGE rep4; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322084">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322084</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148004</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148004</ID>
          <LABEL>GSM3148004</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148004</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148005" accession="SRX4106292">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106292</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148005</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148005: EARLY STAGE rep5; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322085">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322085</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148005</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148005</ID>
          <LABEL>GSM3148005</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148005</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148006" accession="SRX4106293">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106293</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148006</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148006: EARLY STAGE rep6; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322086">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322086</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148006</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148006</ID>
          <LABEL>GSM3148006</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148006</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148007" accession="SRX4106294">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106294</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148007</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148007: EARLY STAGE rep7; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322087">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322087</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148007</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148007</ID>
          <LABEL>GSM3148007</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148007</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148008" accession="SRX4106295">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106295</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148008</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148008: EARLY STAGE rep8; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322088">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322088</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148008</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148008</ID>
          <LABEL>GSM3148008</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148008</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148009" accession="SRX4106296">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106296</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148009</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148009: EARLY STAGE rep9; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322090">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322090</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148009</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148009</ID>
          <LABEL>GSM3148009</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148009</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148010" accession="SRX4106297">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106297</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148010</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148010: EARLY STAGE rep10; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322091">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322091</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148010</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148010</ID>
          <LABEL>GSM3148010</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148010</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148011" accession="SRX4106298">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106298</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148011</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148011: EARLY STAGE rep11; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322089">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322089</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148011</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148011</ID>
          <LABEL>GSM3148011</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148011</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148012" accession="SRX4106299">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106299</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148012</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148012: LATE STAGE rep1; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322092">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322092</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148012</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148012</ID>
          <LABEL>GSM3148012</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148012</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148013" accession="SRX4106300">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106300</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148013</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148013: LATE STAGE rep2; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322093">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322093</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148013</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148013</ID>
          <LABEL>GSM3148013</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148013</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148014" accession="SRX4106301">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106301</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148014</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148014: LATE STAGE rep3; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322094">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322094</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148014</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148014</ID>
          <LABEL>GSM3148014</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148014</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148015" accession="SRX4106302">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106302</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148015</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148015: LATE STAGE rep4; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322096">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322096</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148015</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148015</ID>
          <LABEL>GSM3148015</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148015</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148016" accession="SRX4106303">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106303</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148016</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148016: LATE STAGE rep5; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322095">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322095</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148016</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148016</ID>
          <LABEL>GSM3148016</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148016</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148017" accession="SRX4106304">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106304</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148017</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148017: LATE STAGE rep6; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322097">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322097</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148017</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148017</ID>
          <LABEL>GSM3148017</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148017</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148018" accession="SRX4106305">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106305</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148018</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148018: LATE STAGE rep7; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322099">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322099</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148018</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148018</ID>
          <LABEL>GSM3148018</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148018</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3148019" accession="SRX4106306">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4106306</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3148019</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3148019: LATE STAGE rep8; Homo sapiens; miRNA-Seq</TITLE>
    <STUDY_REF accession="SRP148568" refname="GSE114711">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148568</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS3322098">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3322098</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3148019</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>miRNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>size fractionation</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <SINGLE/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA from all 3 fractions (whole plasma, EVs and EV-depleted) was isolated using the Qiagen miRNeasy kit (Qiagen) and eluted twice with 30uL H2O. RNA was isolated from 100 uL of plasma using the Qiagen miRNeasy Mini prep kit and eluted from the binding column in 15 uL H2O. The quality and quantity of RNA was checked with Bioanalyzer. The small RNA sequencing library was constructed with NEBNext library construction kit following manufacture's instruction. The library with proper insert size was selected by using PippinHT from Sage Scientific. For pooling samples, NEBNext Library Quant Kit was used to quantify the library and equimolar amount of libraries from different samples was pooled for sequencing using Illumina NextSeq 500 (50 bp single-end reads were generated).</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>NextSeq 500</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303148019</ID>
          <LABEL>GSM3148019</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3148019</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
</EXPERIMENT_SET>
