<?xml version="1.0" encoding="UTF-8"?>
<EXPERIMENT_SET xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <EXPERIMENT accession="SRX4110187" alias="CSinden111">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110187</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden111</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325774">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325774</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221510</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden111</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110188" alias="CSinden119">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110188</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden119</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, fresh soil mixture</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325773">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325773</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221516</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden119</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110189" alias="CSinden114">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110189</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden114</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325676">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325676</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221512</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden114</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110190" alias="CSinden100">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110190</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden100</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325677">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325677</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221505</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden100</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110191" alias="CSinden099">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110191</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden099</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325678">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325678</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221504</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden099</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110192" alias="CSinden090">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110192</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden090</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325679">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325679</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221497</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden090</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110193" alias="CSinden108">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110193</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden108</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325680">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325680</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221507</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden108</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110194" alias="CSinden120">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110194</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden120</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, fresh soil mixture</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325681">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325681</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221517</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden120</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110195" alias="CSinden106">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110195</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden106</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325682">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325682</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221506</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden106</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110196" alias="CSinden109">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110196</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden109</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325683">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325683</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221508</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden109</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110197" alias="CSinden095">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110197</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden095</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325684">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325684</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221501</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden095</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110198" alias="CSinden035">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110198</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden035</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325685">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325685</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221465</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden035</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110199" alias="CSinden034">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110199</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden034</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325686">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325686</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221464</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden034</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110200" alias="CSinden038">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110200</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden038</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325687">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325687</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221467</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden038</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110201" alias="CSinden036">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110201</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden036</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325688">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325688</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221466</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden036</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110202" alias="CSinden040">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110202</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden040</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325689">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325689</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221469</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden040</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110203" alias="CSinden039">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110203</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden039</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325690">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325690</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221468</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden039</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110204" alias="CSinden048">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110204</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden048</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325691">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325691</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221471</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden048</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110205" alias="CSinden046">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110205</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden046</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325692">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325692</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221470</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden046</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110206" alias="CSinden050">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110206</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden050</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325693">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325693</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221473</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden050</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110207" alias="CSinden049">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110207</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden049</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325694">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325694</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221472</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden049</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110208" alias="CSinden070">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110208</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden070</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325695">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325695</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221485</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden070</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110209" alias="CSinden069">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110209</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden069</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325696">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325696</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221484</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden069</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110210" alias="CSinden078">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110210</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden078</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325697">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325697</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221491</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden078</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110211" alias="CSinden076">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110211</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden076</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325698">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325698</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221490</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden076</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110212" alias="CSinden075">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110212</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden075</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325699">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325699</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221489</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden075</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110213" alias="CSinden074">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110213</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden074</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325700">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325700</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221488</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden074</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110214" alias="CSinden014">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110214</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden014</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325701">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325701</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221452</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden014</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110215" alias="CSinden015">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110215</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden015</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325702">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325702</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221453</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden015</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110216" alias="CSindenNegPCR2">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110216</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSindenNegPCR2</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, negative PCR reaction</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325703">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325703</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221519</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSindenNegPCR2</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110217" alias="CSinden113">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110217</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden113</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325704">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325704</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221511</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden113</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110218" alias="CSinden008">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110218</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden008</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325705">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325705</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221447</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden008</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110219" alias="CSinden008B">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110219</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden008B</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325706">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325706</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09223215</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden008B</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110220" alias="CSinden006">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110220</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden006</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325707">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325707</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221446</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden006</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110221" alias="CSinden006B">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110221</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden006B</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325709">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325709</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09223214</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden006B</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110222" alias="CSinden011">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110222</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden011</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325708">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325708</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221450</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden011</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110223" alias="CSinden013">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110223</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden013</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325710">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325710</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221451</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden013</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110224" alias="CSinden009">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110224</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden009</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325711">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325711</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221448</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden009</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110225" alias="CSinden010">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110225</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden010</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325712">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325712</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221449</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden010</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110226" alias="CSinden091">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110226</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden091</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325713">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325713</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221498</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden091</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110227" alias="CSinden093">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110227</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden093</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325714">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325714</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221499</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden093</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110228" alias="CSindenNegExtr">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110228</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSindenNegExtr</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, negative DNA extract</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325715">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325715</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221518</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSindenNegExtr</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110229" alias="CSinden086">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110229</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden086</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325716">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325716</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221494</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden086</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110230" alias="CSinden080">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110230</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden080</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325717">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325717</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221493</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden080</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110231" alias="CSinden031">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110231</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden031</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325718">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325718</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221462</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden031</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110232" alias="CSinden033">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110232</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden033</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325719">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325719</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221463</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden033</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110233" alias="CSinden079">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110233</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden079</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325720">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325720</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221492</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden079</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110234" alias="CSinden088">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110234</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden088</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325721">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325721</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221495</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden088</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110235" alias="CSinden016">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110235</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden016</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325722">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325722</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221454</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden016</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110236" alias="CSinden018">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110236</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden018</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325723">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325723</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221455</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden018</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110237" alias="CSinden019">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110237</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden019</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325724">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325724</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221456</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden019</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110238" alias="CSinden020">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110238</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden020</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2012</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325725">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325725</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221457</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden020</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110239" alias="CSinden026">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110239</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden026</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325726">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325726</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221458</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden026</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110240" alias="CSinden028">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110240</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden028</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325727">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325727</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221459</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden028</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110241" alias="CSinden029">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110241</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden029</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325728">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325728</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221460</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden029</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110242" alias="CSinden030">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110242</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden030</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325729">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325729</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221461</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden030</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110243" alias="CSinden054">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110243</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden054</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325730">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325730</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221476</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden054</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110244" alias="CSinden055">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110244</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden055</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325731">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325731</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221477</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden055</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110245" alias="CSinden051">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110245</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden051</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325732">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325732</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221474</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden051</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110246" alias="CSinden053">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110246</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden053</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325733">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325733</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221475</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden053</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110247" alias="CSinden064">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110247</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden064</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2015</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325734">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325734</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221480</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden064</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110248" alias="CSinden065">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110248</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden065</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2015</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325735">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325735</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221481</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden065</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110249" alias="CSinden061">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110249</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden061</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2015</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325736">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325736</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221478</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden061</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110250" alias="CSinden063">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110250</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden063</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2015</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325737">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325737</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221479</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden063</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110251" alias="CSindenNegPCR3">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110251</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSindenNegPCR3</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, negative PCR reaction</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325738">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325738</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221520</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSindenNegPCR3</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110252" alias="CSindenNegPCR4">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110252</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSindenNegPCR4</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, negative PCR reaction</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325739">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325739</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221521</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSindenNegPCR4</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110253" alias="CSinden066">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110253</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden066</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325740">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325740</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221482</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden066</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110254" alias="CSinden068">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110254</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden068</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2014</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325741">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325741</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221483</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden068</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110255" alias="CSinden096">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110255</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden096</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325742">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325742</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221502</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden096</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110256" alias="CSinden098">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110256</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden098</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1979</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325743">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325743</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221503</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden098</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110257" alias="CSinden116">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110257</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden116</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, fresh soil mixture</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325744">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325744</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221514</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden116</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110258" alias="CSinden118">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110258</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden118</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, fresh soil mixture</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325745">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325745</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221515</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden118</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110259" alias="CSinden073">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110259</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden073</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325746">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325746</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221487</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden073</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110260" alias="CSinden115">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110260</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden115</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, original soil site</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325747">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325747</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221513</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden115</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110261" alias="CSinden089">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110261</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden089</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2006</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325748">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325748</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221496</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden089</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110262" alias="CSinden071">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110262</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden071</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 2013</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325750">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325750</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221486</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden071</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110263" alias="CSinden110">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110263</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden110</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1964</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325749">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325749</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221509</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden110</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
  <EXPERIMENT accession="SRX4110264" alias="CSinden094">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX4110264</PRIMARY_ID>
      <SUBMITTER_ID namespace="SUB4053281">CSinden094</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>16S rRNA amplicon sequencing of bacterial soil community: Chronosequence open-cast mine Inden, reclaimed in year 1990</TITLE>
    <STUDY_REF accession="SRP148625">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP148625</PRIMARY_ID>
        <EXTERNAL_ID namespace="BioProject">PRJNA454771</EXTERNAL_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION>Total DNA was extracted from 0.25 g of soil using the PowerSoil DNA Isolation Kit (MO BIO Laboratories, Inc., Carlsbad, US-CA) according to the manufacturer's instructions After extraction, DNA concentrations and sample qualities were assessed on a Fragment Analyzer device (Advanced Analytical Technologies, Inc., Ames, US-IA). From 10 ng input DNA we amplified the V1-V2 region of the bacterial 16S rRNA gene using the primers S-D-Bact-0008-a-S-16 (5?-AGAGTTTGATCMTGGC-3?) and S-D-Bact-0343-a-A-15 (5'-CTGCTGCCTYCCGTA-3') (Klindworth et al. 2013). PCR reactions were carried out in triplicate to compensate for random differences in amplification. The NEBNext High-Fidelity 2X PCR Master Mix (New England Biolabs, Ipswich, US-MA) was used with an initial denaturation step of 5 min at 98 C followed by 25 cycles  denaturation 10 s 98 C; annealing 30 s 60 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. The amplification was checked on a 1% agarose gel before pooling the triplicate reactions for purification with the NucleoSpin Gel and PCR Clean-up Kit (Macherey-Nagel GmbH &amp; Co. KG, Dren, Germany). The samples were then subjected to quality control and concentration measurement on the Fragment Analyzer device. Thereafter, 10 ng of amplified DNA per sample were indexed for multiplexed short-read sequencing using the Nextera XT Index Kit v2 (Illumina, Inc., San Diego, US-CA). The according PCR program consisted of an initial denaturation step of 30 s at 98 C followed by 8 cycles  denaturation 10 s 98 C; annealing 30 s 55 C; elongation 30 s 72 C  and a final elongation time of 5 min at 72 C. Quality controls and concentration measurements of the indexed amplicons were analogous to the previous step. After diluting to 4 nM, the samples were pooled for sequencing on a MiSeq System (Illumina, Inc.) using the MiSeq Reagent Kit v3 (600 cycle) for paired end sequencing following the manufacturer's instructions. A final amount of 10 pmol of DNA was loaded, including 20% of PhiX (Illumina, Inc.) as a postive control.</DESIGN_DESCRIPTION>
      <SAMPLE_DESCRIPTOR accession="SRS3325751">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS3325751</PRIMARY_ID>
          <EXTERNAL_ID namespace="BioSample">SAMN09221500</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_NAME>CSinden094</LIBRARY_NAME>
        <LIBRARY_STRATEGY>AMPLICON</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>METAGENOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>PCR</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>Illumina MiSeq</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
  </EXPERIMENT>
</EXPERIMENT_SET>
