<?xml version="1.0" encoding="UTF-8"?>
<EXPERIMENT_SET xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <EXPERIMENT alias="GSM3724764" accession="SRX5696058">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696058</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724764</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724764: WT rep1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635328">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635328</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724764</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724764</ID>
          <LABEL>GSM3724764</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724764</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724765" accession="SRX5696059">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696059</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724765</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724765: NF1-KO rep1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635329">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635329</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724765</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724765</ID>
          <LABEL>GSM3724765</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724765</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724766" accession="SRX5696060">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696060</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724766</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724766: NF1-KO rep2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635330">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635330</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724766</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724766</ID>
          <LABEL>GSM3724766</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724766</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724767" accession="SRX5696061">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696061</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724767</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724767: NF1-KO rep3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635331">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635331</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724767</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724767</ID>
          <LABEL>GSM3724767</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724767</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724768" accession="SRX5696062">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696062</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724768</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724768: RB1;TP53-cKO rep1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635332">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635332</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724768</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724768</ID>
          <LABEL>GSM3724768</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724768</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724769" accession="SRX5696063">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696063</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724769</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724769: RB1;TP53-cKO rep2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635333">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635333</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724769</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724769</ID>
          <LABEL>GSM3724769</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724769</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724770" accession="SRX5696064">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696064</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724770</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724770: RB1;TP53-cKO rep3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635334">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635334</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724770</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724770</ID>
          <LABEL>GSM3724770</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724770</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724771" accession="SRX5696065">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696065</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724771</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724771: NF1;TP53-cKO rep1; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635336">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635336</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724771</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724771</ID>
          <LABEL>GSM3724771</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724771</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724772" accession="SRX5696066">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696066</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724772</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724772: NF1;TP53-cKO rep2; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635335">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635335</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724772</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724772</ID>
          <LABEL>GSM3724772</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724772</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
  <EXPERIMENT alias="GSM3724773" accession="SRX5696067">
    <IDENTIFIERS>
      <PRIMARY_ID>SRX5696067</PRIMARY_ID>
      <SUBMITTER_ID namespace="GEO">GSM3724773</SUBMITTER_ID>
    </IDENTIFIERS>
    <TITLE>GSM3724773: NF1;TP53-cKO rep3; Danio rerio; RNA-Seq</TITLE>
    <STUDY_REF accession="SRP192755" refname="GSE129899">
      <IDENTIFIERS>
        <PRIMARY_ID>SRP192755</PRIMARY_ID>
      </IDENTIFIERS>
    </STUDY_REF>
    <DESIGN>
      <DESIGN_DESCRIPTION/>
      <SAMPLE_DESCRIPTOR accession="SRS4635337">
        <IDENTIFIERS>
          <PRIMARY_ID>SRS4635337</PRIMARY_ID>
          <EXTERNAL_ID namespace="GEO">GSM3724773</EXTERNAL_ID>
        </IDENTIFIERS>
      </SAMPLE_DESCRIPTOR>
      <LIBRARY_DESCRIPTOR>
        <LIBRARY_STRATEGY>RNA-Seq</LIBRARY_STRATEGY>
        <LIBRARY_SOURCE>TRANSCRIPTOMIC</LIBRARY_SOURCE>
        <LIBRARY_SELECTION>cDNA</LIBRARY_SELECTION>
        <LIBRARY_LAYOUT>
          <PAIRED/>
        </LIBRARY_LAYOUT>
        <LIBRARY_CONSTRUCTION_PROTOCOL>Total RNA was extracted using RNeasy Micro Kit (Cat# 74004, Qiagen)following the manufacturer's instructions and checked for a RIN number to inspect RNA integrity by an Agilent Bioanalyzer 2100 (Agilent technologies, Santa Clara, CA, US).Qualified total RNA was further purified by RNAClean XP Kit (Cat A63987, Beckman Coulter,Inc.Kraemer Boulevard Brea, CA,USA)and RNase-Free DNase Set  (Cat#79254, QIAGEN, GmBH, Germany). RNA libraries were prepared for sequencing using standard Illumina protocols</LIBRARY_CONSTRUCTION_PROTOCOL>
      </LIBRARY_DESCRIPTOR>
    </DESIGN>
    <PLATFORM>
      <ILLUMINA>
        <INSTRUMENT_MODEL>HiSeq X Ten</INSTRUMENT_MODEL>
      </ILLUMINA>
    </PLATFORM>
    <EXPERIMENT_LINKS>
      <EXPERIMENT_LINK>
        <XREF_LINK>
          <DB>gds</DB>
          <ID>303724773</ID>
          <LABEL>GSM3724773</LABEL>
        </XREF_LINK>
      </EXPERIMENT_LINK>
    </EXPERIMENT_LINKS>
    <EXPERIMENT_ATTRIBUTES>
      <EXPERIMENT_ATTRIBUTE>
        <TAG>GEO Accession</TAG>
        <VALUE>GSM3724773</VALUE>
      </EXPERIMENT_ATTRIBUTE>
    </EXPERIMENT_ATTRIBUTES>
  </EXPERIMENT>
</EXPERIMENT_SET>
