# id kazusa:SE1_S01_M06_D02.info.txt sample_set id SE1 title Arabidopsis thaliana leaf metabolite analysis description Investigation of Arabidopsis thaliana leaf metabolites. 6 replicates data are examined for each sample. authors Takeshi Ara, Ryosuke Sasaki, Mitsuo Enomoto, Nozomu Sakurai, Hideyuki Suzuki, Daisuke Shibata, Kazusa DNA Research Institute reference Direct Submittion comment version 6 sample id S01 title Arabidopsis wt leaf organism_scientific_name Arabidopsis thaliana organism_id NCBI taxonomy:3702 compound_id compound_source preparation Arabidopsis thaliana Col-0 seeds are sown on pots filled by vemiculite and are grown in an incubator with 18h Light/6h Dark and 22 degree C condition. After 2 months later, all leafs are harvested. comment [KomicMarket ID] KSBA_11 analytical_method id M06 analytical_method_details_id MS1 sample_amount 6.7 mg comment [MassBase ID] MDLC1_05716 data_analysis id D02 data_analysis_details_id DS2 recommended_decimal_places_of_mass 6|ITMS 2 comment analytical_method_details id MS1 title LC-FT-ICR-MS ESI positive method 1 instrument Agilent1100 HPLC (Agilent), LTQ-FT (Thermo Fisher Scientific) instrument_type LC-FTICR-MS ionization_method ESI ion_mode Positive description Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC conditions: Agilent 1100 series (Agilent), Column: TSKgel-100V (4.6 x 250 mm, 5ƒÊm; TOSOH), Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.), Gradient: (B);3 to 30% (0.0 to 25.0 min), 30 to 90% (25.0 to 40.0 min), 90% (40.0 to 45.0 min), 95% (45.1 to 50.0 min), 3% (50.1 to 57.0 min), Column temp.: 30 degree C, Flow rate=0.5mL/min, PDA: 200-650 nm (2 nm step). FT-ICR-MS conditions: Filter 1: FTMS + c norm !corona !pi res=100000 o(200.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1)., Rejected mass=256.2000;266.0000;284.2000;300.2000;328.2000;344.2000;372.2000;388.2000;416.3000;432.3000;460.0000. comment_of_details data_analysis_details id DS2 title PowerGet analysis B2 description Raw data files are converted to text file by MSGet software without cut off value and peaks are extracted from the text files by PowerFT with parameters (intensity cut off=5000, peak selection filter is default, peak shape is manually checked for peaks with intensity < 1000). The replicates data are aligned by PowerMatch with blank data. The alignment is manually edited. Assigned peaks observed in multiple replicate samples are selected for annotation process. comment_of_details