MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS107 Study Title Physcomitrella patens metabolite analysis using stable isotopes Study Description Metabolites in the Physcomitrella patens are investigated by using stable isotope labelings. This analysis was performed to estimate the elemental composition with high reliability using the number of stable isotopes incorporated in the compound as an index and to add information to discuss the biosynthetic pathway. The Physcomitrella patens were labeled with 13C, 15N, 18O, and 34S, respectively in the same condition. Following peak picking by using PowerGet, the metabolite list was prepared from unlabeled data and blank data. The isotopic peaks were searched and listed using ShiftedIonsFinder. Moreover, the flavonoid-like peaks were also searched using ShiftedIonsFinder. Experimental Design species design Experimental Factor Name Experimental Factor Type Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID Publication DOI DOI: 10.5511/plantbiotechnology.20.0525b Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Mass spectrometry 3 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description The gametophore of P. patens were grown on solid (0.5 % phytagel) half strength Murashige-Skoog (MS) medium containing 0.5% glucose at 22 degree C under 18 h-light/6 h-dark long day condition using sealed-glass bottle system for 2 months. Gametophores were harvested as three biological replicates, frozen in liquid nitrogen, and then lyophilized. 80% methanol was prepared from methanol (Optima LC/MS, Fisher Chemical) and water (Optima LC/MS, Fisher Chemical) for a blank sample. 80% methanol was prepared from methanol (Optima LC/MS, Fisher Chemical) and water (Optima LC/MS, Fisher Chemical). 5 microL sample is injected into HPLC after 0.2 micrometre membrane filter treatment. Instrument: Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: Elute monitoring by PDA equipped with Agilent1200 HPLC in 2 nm step.; Max wave length for elute monitering: 950.0 nm; Min wave length for elute monitering: 190.0 nm; Column name: TSKgel ODS-100V (4.6 x 250 mm, 5 micrometer; TOSOH); Column temperature: 40.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B) 3 to 97% for 45 min, 97% for 5 min and 97 to 3% for 7 min; Flow rate: 0.5 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.) Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1).; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resolution: 60000; Scan mass range: m/z 100.0-1500.0 Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1).; Reject Mass List:141.95862, 154.11863, 158.00286, 158.96133, 171.14920, 182.98518, 186.95629, 195.08766, 232.98007, 235.15326, 235.18047, 249.20608, 262.17214, 391.28446, 436.34244.; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resolution: 60000; Scan mass range: m/z 100.0-1500.0 Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1).; Reject Mass List:102.09139, 110.02006, 141.95860, 158.00286, 158.96135, 163.13289, 171.14921, 182.98517, 186.95628, 195.08767, 199.98790, 207.15909, 223.06365, 224.18561, 227.98281, 232.98011, 235.18048, 249.20600, 266.23260.; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resolution: 60000; Scan mass range: m/z 100.0-1500.0 data not submitted data not submitted Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer Protocol Software Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Public Release Date 2024-06-14 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS107.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry orbitrap Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14184 Comment[Related study] Metabolonote:SE44 Comment[Contributor] Hideki Nagasaki 1, Sachiko Osawa 1, Hideki Hirakawa 1, Yasuhide Hiraga 1,2, Yoshiki Nagashima 1, Nozomu Sakurai 1, Hideyuki Suzuki 1,2, Kota Kera 1,3 (1:Kazusa DNA Research Institute, 2:Hirata Corporation, 3:Faculty of Applied Bioscience, Tokyo University of Agriculture) Comment[Submission Date] 2022-05-22 Comment[Last Update Date] 2024-06-14