MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS108 Study Title LC-MS analysis of parsley Study Description Comprehensive analysis of metabolites in parsley (Petroselium crispum, Paramount) was performed by several combination of sample preparation and analytical conditions. Parsley was hydroponically grown in a greenhouse or a cultivation shelf using control medium and stable isotope (15N or 34S)-containing medium. Experimental Design species design growth condition design Experimental Factor Name treatment tissue Experimental Factor Type treatment tissue Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID 28455528 Publication DOI Protocol Name Sample collection 1 Sample collection 2 Sample collection 3 Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Mass spectrometry 3 Mass spectrometry 4 Mass spectrometry 5 Mass spectrometry 6 Mass spectrometry 7 Mass spectrometry 8 Mass spectrometry 9 Mass spectrometry 10 Mass spectrometry 11 Mass spectrometry 12 Data processing Metabolite identification Protocol Type Sample collection Sample collection Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description The parsley seeds (Kaneko Seeds, Co. LTD. KS100-542, Gunma, Japan) were germinated on watered sand. The 20 days-old seedlings were transplanted on baked foamed clay pebbles (Hydroball, Toshi Engei Col. LTD, Saitama, Japan) in a green house, and grown 63 days with culture medium containing 3 mM KNO3, 1 mM Ca(NO3)2, 0.5 mM MgSO4, 0.5 mM NH4H2PO4, 50 microM Fe-EDTA, 49 microM H3BO3, 9 microM MnSO4, 0.8 microM ZnSO4, 0.3 microM CuSO4, and 0.1 microM Na2MoO4. Shoot was harvested, ground to powder in liquid nitrogen by mortar and pestle, and stored at -80 degree C until use. The parsley seeds (Kaneko Seeds Co. LTD., KS100-542, Gunma, Japan) were germinated on a watered filter paper (Whatman 1002-150, GE Healthcare Japan) in a petri dish, and seedlings were grown 14 days in a cultivation shelf under fluorescent lamps (Biolux-A, NEC Corp., Tokyo, Japan) in 16 hr light / 8 hr dark regime at 25 degree C. The seedlings were transplanted on vermiculite (10865595 SK Agri K.K., Gunma, Japan), and grown 164 days under the same condition fertilizing with a culture medium containing 3 mM KNO3, 1 mM Ca(NO3)2, 0.5 mM MgSO4, 0.5 mM NH4H2PO4, 50 microM Fe-EDTA, 49 microM H3BO3, 9 microM MnSO4, 0.8 microM ZnSO4, 0.3 microM CuSO4, and 0.1 microM Na2MoO4. Shoot was harvested, ground to powder in liquid nitrogen by mortar and pestle, and stored at -80 degree C until use. The same procedure of metabolite extraction and analysis were performed without parsley materials. Frozen powder of plant material was extracted with three times volumes of methanol containing 25 uM of 7-hydroxy-5-methylflavone as an internal standard. After homogenization using a Mixer Mill MM 300 (Quiagen) at 25 Hz for 2 min twice, homogenates were centrifuged (17,400 g, 5 min, 4 degree C). The supernatant was filtered through 0.2 um PTFE membrane (Millipore). Hydrophobic compounds in the filtrate were removed by absorbing to C18 silica column (MonoSpin C18, GL Science, Tokyo, Japan). Instrument: Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: The flow rate was set to 0.25 ml/min (0-100 min) and 0.5 ml/min (100.1-107 min). The flow rate was set to 0.5 ml/min, and the column oven temperature was set at 40 degree C.; Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSK-gel column ODS-100V (4.6 x 250 mm, 5 micrometre; TOSOH); Column temperature: 40.0 degree C; Column type: ODS; Elute monitor: photodiode array detector; Flow gradient: The gradient program was as follows: 3% B (0 min), 97% B (90 min), 97% B (100 min), 3% B (100.1 min), and 3% B (107 min). ; Flow rate condition: solvent B:The flow rate was set to 0.25 ml/min (0-100 min) and 0.5 ml/min (100.1-107 min). ; Solvent: Water (HPLC grade; solvent A) and acetonitrile (HPLC grade; solvent B) were used as the mobile phase with 0.1% v/v formic acid added to both solvents. Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively. Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 30.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 2; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 30.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was not applied.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 12,500, MS2 scans for the most intense 5 ions of full mass scan with IT, and MS3 scans for the most 2 ions of MS2 scan with IT. A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 12,500 and MS2 scan for the most intense 5 ions of full mass scan with FT-ICR.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 30.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 2; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 30.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C; Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was not applied.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 12,500, MS2 scans for the most intense 5 ions of full mass scan with IT, and MS3 scans for the most 2 ions of MS2 scan with IT. A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 12,500; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 12,500 and MS2 scan for the most intense 5 ions of full mass scan with FT-ICR.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 12,500; Scan mass range: m/z 100-1500; Spray voltage 4.0 kV; Capillary temperature 300 degree C data not submitted data not submitted Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) Protocol Software Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Xcalibur software version 2.07 (Thermo Fisher Scientific) Public Release Date 2024-06-14 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS108.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry fourier transform ion cyclotron resonance mass spectrometry Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14186 Comment[Related study] Metabolonote:SE61 Comment[Contributor] Hideki Nagasaki, Sachiko Osawa, Hideki Hirakawa, Nozomu Sakurai, Kunihiro Suda (Kazusa DNA Research Institute) Comment[Submission Date] 2022-05-22 Comment[Last Update Date] 2024-06-14