MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS109 Study Title LC-MS analysis of 15 vegetables and fruits Study Description This study is aimed to a comprehensive annotation of metabolites in major vegetables and fruits produced in Japan. Experimental Design species design Experimental Factor Name organism Experimental Factor Type organism Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID 28455528 Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description Plant samples were prepared from materials purchased at a local market in Tochigi prefecture, Japan. The parts of plant materials were prepared from three individual materials sold, freeze-dried, ground to powder in mortar and pestle, mixed three preparations, and stored at -80 degree C until use. Mock sample was prepared with the same procedure without adding the plant material and with 100% methanol containing 25 µM of 7-hydroxy-5-methylflavone as an internal standard. Freeze-dried powder of plant material was extracted with 75% methanol containing 25 microM of 7-hydroxy-5-methylflavone as an internal standard. After homogenization using a Mixer Mill MM 300 (Quiagen) at 25 Hz for 2 min twice, homogenates were centrifuged (17,400 g, 5 min, 4 degree C). The supernatant was filtered through 0.2 micrometre PTFE membrane (Millipore). Hydrophobic compounds in the filtrate were removed by absorbing to C18 silica column (MonoSpin C18, GL Science, Tokyo, Japan). Instrument: Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: The flow rate was set to 0.25 ml/min (0-100 min) and 0.5 ml/min (100.1-107 min). The flow rate was set to 0.5 ml/min, and the column oven temperature was set at 40 degree C.; Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSK-gel column ODS-100V (4.6 x 250 mm, 5 micrometre; TOSOH); Column temperature: 40.0 degree C; Column type: ODS; Elute monitor: photodiode array detector; Flow gradient: The gradient program was as follows: 3% B (0 min), 97% B (90 min), 97% B (100 min), 3% B (100.1 min), and 3% B (107 min). ; Flow rate condition: solvent B:The flow rate was set to 0.25 ml/min (0-100 min) and 0.5 ml/min (100.1-107 min). ; Solvent: Water (HPLC grade; solvent A) and acetonitrile (HPLC grade; solvent B) were used as the mobile phase with 0.1% v/v formic acid added to both solvents. Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 100,000 and MS2 scans for the most intense 5 ions of full mass scan with ion trap (IT). A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 100,000; Scan mass range: m/z 100-1500; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively. Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Comment: Multistage MSn analyses were carried out using collision induced dissociation (CID) in a linear ion trap detector at a normalized collision energy of 35.0% and an isolation width of 4.0 (m/z), and monitored by both ion trap detector and FT-ICR detector at 25,000 (at m/z 400) mass resolution.; MS scan setting: Mass scan events were set as follows: full mass scan with FT-ICR in resolution 12,500, MS2 scans for the most intense 5 ions of full mass scan with IT, and MS3 scans for the most 2 ions of MS2 scan with IT. A dynamic exclusion setting was applied as follows: repeat count, 3; repeat duration, 30 sec; exclusion list size, 500; margin, 10 ppm, and exclusion duration, 20.; Data processing software: Xcalibur software version 2.07 (Thermo Fisher Scientific); Fragmentation method: Collision Induced Dissociation (CID); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resoluton: Full mass scan with FT-ICR in resolution 12,500; Scan mass range: m/z 100-1500; Sheath gas: Nitrogen sheath gas and auxiliary gas were set at 40 and 15 arbitrary units, respectively.; data not submitted data not submitted Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) Protocol Software Xcalibur software version 2.07 (Thermo Fisher Scientific) Public Release Date 2024-06-14 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS109.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry fourier transform ion cyclotron resonance mass spectrometry Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14186 Comment[Related study] Metabolonote:SE62 Comment[Contributor] Hideki Nagasaki 1, Sachiko Osawa 1, Hideki Hirakawa 1, Nozomu Sakurai 1, Kunihiro Suda 1, Shingo Takahashi 2 (1:Kazusa DNA Research Institute 2:KAGOME CO., LTD.) Comment[Submission Date] 2022-05-22 Comment[Last Update Date] 2026-10-20