MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS114 Study Title LC-MS analysis of boiled squash Study Description Metabolites of raw and boiled squash (Cucurbita maxima) were analyzed using liquid chromatography-mass spectrometry Experimental Design organism status design Experimental Factor Name treatment Experimental Factor Type treatment Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Description Plant matrials are purchased at the local market. Methanol extraction Instrument: Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: Elute monitoring by PDA equipped with Agilent1100 HPLC in 2 nm step.; Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSKgel ODS-100V (4.6 x 250 mm; TOSOH); Column temperature: 40.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B);3 to 97% (0.0 to 45.0 min), 97% (45.1 to 50.0 min), 3% (50.1 to 57.0 min); Flow rate: 0.5 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid) Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1)., Rejected mass=144.98000, 146.98000, 158.00000, 171.15000, 195.09000, 202.13000.; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resoluton: 60000; Scan mass range: m/z 100.0-1500.0 Xcalibur (Thermo Fisher Scientific K.K); In annotation process, KEGG, KNApSAcK and LipidMAPS are used for primary database search. Peaks with no hit to these databases are then selected to secondary search using exactMassDB databases. Peaks without predicted molecular formula are assigned as "unidentified" peak. Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer Protocol Software Xcalibur (Thermo Fisher Scientific K.K) Xcalibur (Thermo Fisher Scientific K.K) PowerGet(Sakurai et al., BioMed Research International, 2014:194812) Public Release Date 2024-06-14 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS114.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry orbitrap Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14187 Comment[Related study] Metabolonote:SE67 Comment[Contributor] Hideki Nagasaki, Sachiko Osawa, Hideki Hirakawa, Nozomu Sakurai, Koei Okazaki, Daisuke Nakajima, Daisuke Shibata (Kazusa DNA Research Institute) Comment[Submission Date] 2022-05-22 Comment[Last Update Date] 2024-06-14