Parameters for D:\Xevo_G2_data\181005_FD_Collection4_01_Seedcol.PRO\ACQUDB\fdda_positive_170624_04_Refill_Always.EXP Created by Masslynx v4.1 Lock Spray Configuration: Reference Scan Frequency(sec) 20.000 Reference Cone Voltage(V) 40.000 Reference Collision Energy 21.000 Reference DRE Setting 99.900 Temperature Correction: Temperature Correction Disabled Instrument Configuration: Lteff 1800.0 Veff 6322.60 Resolution 15000 Min Points in Peak 2 Acquisition Device WatersADC ADC Trigger Threshold (V) 1.00 ADC Input Offset (V) -1.53 Average Single Ion Intensity 33 ADC Amplitude Threshold 3 ADC Centroid Threshold -1 ADC Ion Area Threshold 3 ADC Ion Area Offset 15 ADC Pushes Per IMS Increment 1 TargetEnhancement Delay Coefficient 2.0000 TargetEnhancement Delay Offset 0.0000 Experimental Instrument Parameters Instrument Parameter Filename D:\Xevo_G2_data\181005_FD_Collection4_01_Seedcol.PRO\ACQUDB\111027_LCMS_CV_20.IPR (MODIFIED) Polarity ES+ Analyser Sensitivity Mode Capillary (kV) 3.0000 Sampling Cone 20.0000 Extraction Cone 4.0000 Source Temperature (°C) 120 Desolvation Temperature (°C) 450 Cone Gas Flow (L/Hr) 50.0 Desolvation Gas Flow (L/Hr) 600.0 LM Resolution 4.7 HM Resolution 15.0 Aperture 1 0.0 Pre-filter 10.0 Ion Energy 1.0 Manual Collision Energy FALSE Collision Energy 6.0 Detector 3300 DetectorCache 0 Sample Infusion Flow Rate (µL/min) 20 Sample Flow State LC Sample Fill Volume (µL) 250 Sample Reservoir Wash LockSpray Infusion Flow Rate (µL/min) 10 LockSpray Flow State Infusion LockSpray Reservoir B LockSpray Capillary (kV) 3.00 Use Manual LockSpray Collision Energy FALSE Collision Energy 6.0 Acceleration1 30.0 Acceleration2 85.0 Aperture2 18.0 Transport1 30.0 Transport2 30.0 Steering -0.60 Tube Lens 18 Pusher 1900.0 Pusher Offset -0.80 Puller 1430.0 Pusher Cycle Time (µs) Automatic Pusher Width (µs) Automatic Collector 50 Collector Pulse 10.0 Stopper 10 Stopper Pulse 20.0 Entrance 17 Static Offset 120 Puller Offset 0.00 Reflectron Grid (kV) 1.706 Flight Tube (kV) 9.00 Reflectron (kV) 1.602 Use Manual Gas Control TRUE Gas Flow (mL/min) 0.20 TWave Entrance 2.00 Static Offset 120.00 TWave Exit 15.00 TWave Trap Height 4.00 TWave Extract Height 5.00 Trap Wave Velocity (m/s) 300 Trap Wave Height (V) 0.5 Backing 1.70e0 Collision 1.38e-2 TOF 8.63e-7 SourceRFOffset 350 TrapRFOffset 380 MS Profile Type Auto P MSProfileMass1 100 MSProfileDwellTime1 20 MSProfileRampTime1 80 MSProfileMass2 500 MSProfileDwellTime2 0 MSProfileRampTime2 0 MSProfileMass3 500 LockMassValidSigma 5 Acquisition mass range Start mass 100.000 End mass 1200.000 Calibration mass range Start mass 91.125 End mass 1449.809 Experiment Reference Compound Name: Leucine Enkephalin Function Parameters - Function 1 - TOF FAST DDA FUNCTION [ACQUISITION] Survey Start Time 0.00 Survey End Time 14.50 [MS SURVEY] Survey Start Mass 100.0000 Survey End Mass 1200.0000 Discard uninteresting scans NO Switch to MS/MS when Intensity rising above threshold Intensity Threshold 50000.0 Survey Scan Time 0.20 Survey Interscan Time 0.01 Survey Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 [MS/MS] MSMS Start Mass 100.0 MSMS End Mass 1200.0 Number of components 6 Switchback threshold (intensity / second) 0.0 Use MSMS to MS Switch After Time YES MSMS Switch After Time (sec) 0.3 Use MSMS to MS Switch After 1 Scan NO Use MSMS to MS Switch After N Scans NO MSMS Scan Time (sec) 0.10 MSMS Interscan Time (sec) 0.01 MSMS Data Format Centroid Use MS/MS ipr File NO [PEAK DETECTION] Use Intensity based Peak Detection YES Peak Detection Window 3.0 Deisotope Peak Selection YES Charge State Tolerance Window 3.0 Charge State Extraction Window 2.0 Deisotope Tolerance Window 3.0 Deisotope Extraction Window 2.0 [COLLISION ENERGY] MSMS Collision Energy Ramp Start (eV) 30.0 MSMS Collision Energy Ramp End (eV) 30.0 MSMS Collision Energy Ramp Low Mass (Da) 100.0 MSMS Collision Energy Ramp High Mass (Da) 1200.0 MSMS Collision Energy Ramp LM Start (eV) 20.0 MSMS Collision Energy Ramp LM End (eV) 50.0 MSMS Collision Energy Ramp HM Start (eV) 20.0 MSMS Collision Energy Ramp HM End (eV) 50.0 ITraQ Mode: disabled [CONE VOLTAGE] Survey Cone Voltage (V) 20.0 Use Tune Page Cone Voltage YES [INCLUDE] Precursor Selection Included Masses Take Priority Use Include Masses List NO Use Include File Masses NO Include Window +/- (mDa) 20.0 Include Retention Time Window 5.0 [EXCLUDE] Use Exclude Masses List NO Use Exclude File Masses NO Lock Mass 278.114100,556.277100 Mass Window +/- 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 2 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO Using Collision Energy Profile YES CE Profile Filename Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 3 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO MSMS Collision Energy Ramp Start (eV) 541.2 MSMS Collision Energy Ramp End (eV) 542.1 MSMS Collision Energy Ramp Low Mass (Da) 0.0 MSMS Collision Energy Ramp High Mass (Da) 0.0 MSMS Collision Energy Ramp LM Start (eV) 0.0 MSMS Collision Energy Ramp LM End (eV) 0.0 MSMS Collision Energy Ramp HM Start (eV) 0.0 MSMS Collision Energy Ramp HM End (eV) 0.0 Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 4 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO MSMS Collision Energy Ramp Start (eV) 614.5 MSMS Collision Energy Ramp End (eV) 614.6 MSMS Collision Energy Ramp Low Mass (Da) 0.0 MSMS Collision Energy Ramp High Mass (Da) 0.0 MSMS Collision Energy Ramp LM Start (eV) 0.0 MSMS Collision Energy Ramp LM End (eV) 0.0 MSMS Collision Energy Ramp HM Start (eV) 0.0 MSMS Collision Energy Ramp HM End (eV) 0.0 Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 5 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO MSMS Collision Energy Ramp Start (eV) 708.4 MSMS Collision Energy Ramp End (eV) 708.5 MSMS Collision Energy Ramp Low Mass (Da) 0.0 MSMS Collision Energy Ramp High Mass (Da) 0.0 MSMS Collision Energy Ramp LM Start (eV) 0.0 MSMS Collision Energy Ramp LM End (eV) 0.0 MSMS Collision Energy Ramp HM Start (eV) 0.0 MSMS Collision Energy Ramp HM End (eV) 0.0 Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 6 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO MSMS Collision Energy Ramp Start (eV) -0.0 MSMS Collision Energy Ramp End (eV) 782.4 MSMS Collision Energy Ramp Low Mass (Da) 0.0 MSMS Collision Energy Ramp High Mass (Da) 0.0 MSMS Collision Energy Ramp LM Start (eV) 0.0 MSMS Collision Energy Ramp LM End (eV) 0.0 MSMS Collision Energy Ramp HM Start (eV) 0.0 MSMS Collision Energy Ramp HM End (eV) 0.0 Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 7 - TOF SURVEY FUNCTION Scan Time (sec) 0.100 Interscan Time (sec) 0.014 Set Mass 0.0 Start Mass 100.0 MSMS End Mass 1200.0 Start Time (mins) 0.00 End Time (mins) 14.50 Data Format Centroid ADC Sample Frequency (GHz) 6.0 ADC Pusher Frequency (µs) 60.0 ADC Pusher Width (µs) 1.50 Use Tune Page Cone Voltage NO Cone Voltage (V) 35.0 Use Auto Collision Energy NO MSMS Collision Energy Ramp Start (eV) 858.8 MSMS Collision Energy Ramp End (eV) -0.0 MSMS Collision Energy Ramp Low Mass (Da) 0.0 MSMS Collision Energy Ramp High Mass (Da) 0.0 MSMS Collision Energy Ramp LM Start (eV) 0.0 MSMS Collision Energy Ramp LM End (eV) 0.0 MSMS Collision Energy Ramp HM Start (eV) 0.0 MSMS Collision Energy Ramp HM End (eV) 0.0 Sensitivity Normal Dynamic Range Normal Save Collapsed Retention Time Data No Use Rule File Filtering No Lock Mass 0.0000 Lock Mass Window 0.5 Scans to Average 3.0 Calibration Dynamic 2 Function Parameters - Function 8 - REFERENCE Scan Time (sec) 0.15 Interval 20 Reference Cone Voltage 40.0 Collision Energy (eV) 21.0 Lock Mass 278.114100,556.277100 Mass Window +/- 0.5 Scans to Average 3.0 Calibration Dynamic 2