MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS219 Study Title A lipidome atlas in MS-DIAL 4 (Mouse tissues IMMS study) Study Description We present Mass Spectrometry-Data Independent Analysis software version 4 (MS-DIAL 4), a comprehensive lipidome atlas with retention time, collision cross-section and tandem mass spectrometry information. We formulated mass spectral fragmentations of lipids across 117 lipid subclasses and included ion mobility tandem mass spectrometry. Using human, murine, algal and plant biological samples, we annotated and semiquantified 8,051 lipids using MS-DIAL 4 with a 1-2% estimated false discovery rate. MS-DIAL 4 helps standardize lipidomics data and discover lipid pathways. This dataset describes an experiment in which mouse tissues were measured with ion mobility MS. Experimental Design software variation design Experimental Factor Name tissue Mass analyzer Data acquisition method Experimental Factor Type tissue Mass analyzer Data acquisition method Person Last Name Takahashi Tsugawa Person First Name Mikiko Hiroshi Person Mid Initials Person Affiliation RIKEN Center for Sustainable Resource Science Tokyo University of Agriculture and Technology; RIKEN Center for Sustainable Resource Science; RIKEN Center for Integrative Medical Sciences Person Roles submitter submitter PubMed ID 32541957 Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description Mouse samples: The adrenal gland, brain, brown adipose tissue, eye, feces, heart, kidney, large intestine, liver, lung, pancreas, skeletal muscle, skin (ear), small intestine, spleen, testis, and white adipose tissues of 8-10 weeks male mice (C57BL/6 J background, CLEA Japan, Tokyo, Japan) were harvested according to the ethical protocol approved by the RIKEN Center for Integrative Medical Sciences (2019-015(2)). The tissues were homogenized by a multi-beads shocker (YASUI KIKAI, Japan) with a metal cone (YASUI KIKAI, Japan) at 1500 x g for 15 s x 2, and MeOH was added to the homogenate according to the tissue weight. After the solvent was homogenized again by the same condition, the appropriate amount of MeOH (<100 microliter) solving 10 mg tissue weight was transferred to a 2-mL glass tube. After the solvent was messed up to 175 microliter by MeOH, 25 microliter of MeOH containing internal standards was added to the solvent, and vortexed for 10 s. After the solvent was incubated for 2 hours on ice, 100 microliter of chloroform was added, and vortexed for 10 s. After the solvent was incubated for 1 hour on ice, 20 microliter of Milli-Q water was added, and vortexed for 10 s. After 10 min incubation on ice, the solvent was centrifugated at 2000 x g for 10 min at 4 degree C, and the supernatant was transferred to the LC-MS vial The LC system consisted of a Waters Acquity UPLC system. Lipids were separated on an Acquity UPLC Peptide BEH C18 column (50 x 2.1 mm; 1.7 micrometer) (Waters, Milford, MA, USA). The column was maintained at 45 degree C at a flow-rate of 0.3 mL/min. The mobile phases consisted of (A) 1:1:3 (v/v/v) acetonitrile:methanol:water with ammonium formate (5 mM) and 10 nM EDTA and (B) 100% isopropanol with ammonium formate (5 mM) and 10 nM EDTA. A sample volume of 0.5-3 microliter, which depended on biological samples, was used for the injection. The separation was conducted under the following gradient: 0 min 0% (B); 1 min 0% (B); 5 min 40% (B); 7.5 min 64% (B); 12 min 64% (B); 12.5 min 82.5% (B); 19 min 85% (B); 20 min 95% (B); 20.1 min 0% (B); and 25 min 0% (B). Sample temperature was maintained at 4 degree C. Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). Data dependent MS/MS acquisition (DDA) was used. The parameters were MS1 mass ranges, m/z 200-2500 and MS2 mass ranges, m/z 50-2500; MS1 cycle time, 0.5 sec; MS2 accumulation 14 Hz ; collision energy, 30 eV; end plate offset, 500 V; capillary voltage, +4.5 kV/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 10.0 l/min; dry temperature, 220 degree C/200 degree C; funnel 1 RF, 300 Vpp; funnel 2 RF, 200 Vpp/250 Vpp; multipole RF, 200 Vpp; deflection delta, +70 V/-70 V; quadrupole ion energy, 6 eV/5 eV; collision transfer energy, 14 eV/15 eV; collision RF, 1100 to 1800 Vpp stepping; transfer time 45 to 75 microsecond stepping; pre-pulse storage, 10 microsecond/5 microsecond; intensity threshold, 31cts.; exclusion time of precursor ion, 0.2 min. The mass calibration was automatically performed using 5 mM sodium acetate calibration solution. Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). Data dependent MS/MS acquisition (DDA) was used. The parameters were MS1 and MS2 mass ranges, m/z 50-2500; MS1 and MS2 accumulation time, 100 ms; mobility range, 0.55-1.90; collision energy 30 eV; end plate offset, 500 V; capillary voltage, +4.5 kV/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 10.0 L/min; dry temperature, 220 degree C; funnel 1 RF, 300 Vpp; funnel 2 RF, 200 Vpp/250 Vpp; multipole RF, 200 Vpp; deflection delta, 70 V/-70 V; quadrupole ion energy, 6 eV/5 eV; collision transfer energy, 14 eV/15 eV; collision RF, 1500 Vpp/1100 Vpp; transfer time 75 microsecond/54 microsecond; pre-pulse storage, 10 microsecond/5 microsecond; tims transfer (delta)1, -20 V/20 V; tims transfer (delta)2, -120 V/120 V; tims transfer (delta)3, 70 V/-70 V; tims transfer (delta)4, 100 V/-100 V; tims transfer (delta)5, 0 V; tims transfer (delta)6, 100 V/-100 V; intensity threshold, 250 cts.; target intensity, 4000 cts; exclusion time of precursor ion, 0.1 min. The mass calibration was automatically performed using 5 mM sodium acetate calibration solution. For the confirmation of ESI(+)-MS/MS spectra for phosphatidylcholine, the positive ion mode data was acquired with the following setting. The parameters were dry temperature, 200 degree C; funnel 2 RF, 250 Vpp; quadrupole ion energy, 5 eV; collision transfer energy, 15 eV; collision RF, 1100 Vpp; and transfer time 54 microsecond; pre-pulse storage, 5 microsecond. The other parameters were the same as Mass spectrometry 1. use MS-DIAL ver.4.0 (For parameters used: Supplementary Table S3e at https://doi.org/10.1038/s41587-020-0531-2). use MS-DIAL ver.4.0 Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer;Data acquisition method Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer;Data acquisition method Protocol Hardware Protocol Software MS-DIAL ver.4.0 MS-DIAL ver.4.0 Public Release Date 2023-06-14 Term Source Name Term Source File Term Source Version SDRF File MTBKS219.sdrf.txt Comment[Study type] lipid profiling Comment[Experiment type] liquid chromatography-mass spectrometry data-dependent acquisition ion mobility spectrometry-mass spectrometry tandem mass spectrometry time-of-flight mass spectrometry quadrupole mass spectrometer Comment[Submission type] LC-MS Comment[BioProject] PRJDB15006 Comment[Related study] Comment[Contributor] Kazutaka Ikeda(Department of Applied Genomics, Kazusa DNA Research Institute; RIKEN Center for Integrative Medical Sciences), Masanori Arita(National Institute of Genetics; RIKEN Center for Sustainable Resource Science), Makoto Arita(RIKEN Center for Integrative Medical Sciences; Graduate School of Pharmaceutical Sciences, Keio University; Graduate School of Medical Life Science, Yokohama City University) Comment[Submission Date] 2022-12-28 Comment[Last Update Date] 2023-06-14