MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS220 Study Title A lipidome atlas in MS-DIAL 4 (Plants IMMS study) Study Description We present Mass Spectrometry-Data Independent Analysis software version 4 (MS-DIAL 4), a comprehensive lipidome atlas with retention time, collision cross-section and tandem mass spectrometry information. We formulated mass spectral fragmentations of lipids across 117 lipid subclasses and included ion mobility tandem mass spectrometry. Using human, murine, algal and plant biological samples, we annotated and semiquantified 8,051 lipids using MS-DIAL 4 with a 1-2% estimated false discovery rate. MS-DIAL 4 helps standardize lipidomics data and discover lipid pathways. This dataset describes Arabidopsis thaliana samples measured with ion mobility MS. Experimental Design software variation design Experimental Factor Name treatment Mass analyzer Data acquisition method Experimental Factor Type treatment Mass analyzer Data acquisition method Person Last Name Takahashi Tsugawa Person First Name Mikiko Hiroshi Person Mid Initials Person Affiliation RIKEN Center for Sustainable Resource Science Tokyo University of Agriculture and Technology; RIKEN Center for Sustainable Resource Science; RIKEN Center for Integrative Medical Sciences Person Roles submitter submitter PubMed ID 32541957 Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description Plants were grown on Murashige and Skoog medium agar plates with 0.5% sucrose in a growth chamber at 22 degreeC under a 16-h-light (40 to 75 micromol/(m^2 s) of fluorescent lamp)/8-h-dark cycle. Seventeen-day-old Col-0 plants at about 3 h after the onset of the light phase were subjected to heat stress at 38 degree C for one day (biological replicate n = 3). Plants grown at 22 degree C were examined as the normal growth condition. Whole upper-ground parts from two different plants were harvested and pooled as a biological replicate. Under cryogenic conditions with liquid nitrogen, the plant material in the 2.0-mL microcentrifuge tube was milled by shaking at 900 rpm for 2 min on the Shake Master Neo (BMS, Tokyo, Japan) using a zirconia bead. From the frozen powdered plant material, total lipids were extracted by adding a 20-fold volume of extraction solvent (20 microliter/mg F.W. plant sample) (chloroform/methanol/water, 50/100/31.45, v/v/v) with 1 microM 1,2-didecanoyl-sn-glycero-3-phosphocholine, Sigma-Aldrich) as the internal standard (20 pmol mg-1 F.W. plant sample). After stirring on a vortex mixer vigorously, the homogenate was incubated for 5 min at room temperature and centrifuged at 10,000xg for 10 min at room temperature. Supernatant (200 microliter) was transferred to a new 1.5-mL microcentrifuge tube and mixed with chloroform (52.6 microliter) and water (52.6 microliter). After stirring on a vortex mixer vigorously, the mixture in the 1.5-mL microcentrifuge tube was incubated on ice for 10 min in darkness and centrifuged at 1,000xg for 10 min. The lower organic layer (85 microliter) was transferred to a new 1.5-mL microcentrifuge tube and dried by the centrifugal concentrator (ThermoSavant SPD2010, Thermo Fisher Scientific) at room temperature. The dried lipid extract was dissolved in 160 microliter of ethanol, centrifuged at 14,000xg for 10 min and transferred to a vial with a glass insert for LC-MS analysis. The LC system consisted of a Bruker Elute UHPLC system. Lipids were separated on an Acquity UPLC HSS T3 C18 column (50 x 1.0 mm; 1.8 micrometer) (Waters, Milford, MA, USA). The column was maintained at 55 degree C at a flow-rate of 0.15 mL/min. The mobile phases consisted of (A) 200:800:10:1 (v/v/v/v) acetonitrile:water:1M ammonium formate:formic acid and (B) 100:900:10:1 (v/v/v/v) acetonitrile:isopropanol:1M ammonium formate:formic acid. A sample volume of 2 microliter was used for the injection. The separation was conducted under the following gradient: 0 min 35% (B); 3 min 70% (B); 7 min 85% (B); 10 min 90% (B); 12 min 90% (B); 12.5 min 35% (B); and 15 min 35% (B). Sample temperature was maintained at 10 degree C. Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). Data dependent MS/MS acquisition (DDA) was used. The parameters were MS1 mass ranges, m/z 200-1600 and MS2 mass ranges, m/z 50-1600; MS1 cycle time time, 0.5 sec; MS2 accumulation, 14 Hz ; collision energy, 30 eV; end plate offset, 500 V; capillary voltage, +4.2/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 8.0 l/min; dry temperature, 200 degree C; funnel 1 RF (radio frequency), 300 Vpp; funnel 2 RF, 250 Vpp; multipole RF, 200 Vpp; deflection delta, 70 V; quadrupole ion energy, 5 eV; collision transfer energy, 8 eV; collision RF, 1100 Vpp; transfer time, 54 microsecond; pre-pulse Storage, 5 microsecond; intensity threshold, 31cts.; exclusion time of precursor ion, 0.2 min. The mass calibration was automatically performed using 5 mM sodium formate calibration solution. Mass spectrometric detection of lipids was performed on a hybrid trapped ion mobility-quadrupole time-of-flight mass spectrometer (timsTOF Pro, Bruker Daltonics, Bremen, Germany). The PASEF mode acquisition, i.e. data dependent MS/MS acquisition with the ion mobility separation, was performed by the following parameters. The parameters were MS1 mass ranges, m/z 200-1600 and MS2 mass ranges, m/z 50-1600; MS1 and MS2 accumulation time, 148.5 ms; mobility range 0.55-1.9; collision energy 30 eV; end plate offset, 500 V; capillary voltage, +4.2/-4.2 kV; nebulizer pressure, 2 bar; dry gas, 8.0 l/min; dry temperature, 200 degree C; funnel 1 RF (radio frequency), 300 Vpp; funnel 2 RF, 250 Vpp; multipole RF, 200 Vpp; deflection delta, 70 V; quadrupole ion energy, 5 eV; collision transfer energy, 15 eV; collision RF, 1100 Vpp; transfer time 54 microsecond; pre-pulse storage, 5 microsecond; tims transfer (delta)1, -20 V/+20 V; tims transfer (delta)2, -120 V/+120 V; tims transfer (delta)3, +70 V/-70 V; tims transfer (delta)4, +100 V/-100 V; tims transfer (delta)5, 0 V; tims transfer (delta)6, +100 V/-100 V; intensity threshold, 2500 cts; target intensity, 20000 cts; exclusion time of precursor ion, 0.1 min. The mass calibration was automatically performed using 5 mM sodium formate calibration solution. use MS-DIAL ver.4.0 (For parameters used: Supplementary Table S3e at https://doi.org/10.1038/s41587-020-0531-2). use MS-DIAL ver.4.0 Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer;Data acquisition method Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer;Data acquisition method Protocol Hardware Protocol Software MS-DIAL ver.4.0 MS-DIAL ver.4.0 Public Release Date 2023-06-14 Term Source Name Term Source File Term Source Version SDRF File MTBKS220.sdrf.txt Comment[Study type] lipid profiling Comment[Experiment type] liquid chromatography-mass spectrometry data-dependent acquisition ion mobility spectrometry-mass spectrometry tandem mass spectrometry time-of-flight mass spectrometry quadrupole mass spectrometer Comment[Submission type] LC-MS Comment[BioProject] PRJDB15006 Comment[Related study] Comment[Contributor] Kazutaka Ikeda(Department of Applied Genomics, Kazusa DNA Research Institute; RIKEN Center for Integrative Medical Sciences), Masanori Arita(National Institute of Genetics; RIKEN Center for Sustainable Resource Science), Makoto Arita(RIKEN Center for Integrative Medical Sciences; Graduate School of Pharmaceutical Sciences, Keio University; Graduate School of Medical Life Science, Yokohama City University) Comment[Submission Date] 2022-12-28 Comment[Last Update Date] 2023-06-14