﻿<?xml version="1.0" encoding="utf-8"?>
<AcqMethod>
  <Version>1.0</Version>
  <!--Method Properties-->
  <MethodName>cation-kamei-F.m</MethodName>
  <MethodPath>D:\MassHunter\data\TOF-1\kamei\210201_C_fukuda-127\6.d\AcqData\cation-kamei-F.m</MethodPath>
  <MethodDescription>Default Method</MethodDescription>
  <!--List of Devices-->
  <DeviceList>Iso Pump</DeviceList>
  <DeviceList>MS TOF</DeviceList>
  <!--Device Specific Setpoints-->
  <IsoPump>
    <ComponentModelName>Iso Pump</ComponentModelName>
    <ComponentModel>G1310A</ComponentModel>
    <ComponentOrdinal>1</ComponentOrdinal>
    <ComponentOptions />
    <Version>1.3.15.0; base: 1.3.18.0</Version>
    <Stoptime>No Limit</Stoptime>
    <Posttime>Off</Posttime>
    <Delay>0</Delay>
    <CONTACT_1>0</CONTACT_1>
    <CONTACT_2>0</CONTACT_2>
    <CONTACT_3>0</CONTACT_3>
    <CONTACT_4>0</CONTACT_4>
    <ContactsTimetable />
    <Signals>
      <SignalDesc>Pressure</SignalDesc>
      <Store>No</Store>
    </Signals>
    <Signals>
      <SignalDesc>Flow</SignalDesc>
      <Store>No</Store>
    </Signals>
    <Signals>
      <SignalDesc>Direction of piston</SignalDesc>
      <Store>No</Store>
    </Signals>
    <StrokeA>Auto</StrokeA>
    <CompressA>50</CompressA>
    <Flow>1</Flow>
    <SolvRatioA>100</SolvRatioA>
    <SolvNameA />
    <PressureMin>0</PressureMin>
    <PressureMax>400</PressureMax>
    <FRamp>100</FRamp>
    <FPTimetable />
  </IsoPump>
  <QTOF>
    <ComponentModel>G6210A</ComponentModel>
    <ComponentName>MS TOF</ComponentName>
    <IonSource>Dual ESI</IonSource>
    <TuneFile>AutoTune.tun</TuneFile>
    <StopMode>NoLimit</StopMode>
    <StopTime>30.00</StopTime>
    <NoWaitForTemp>Enable</NoWaitForTemp>
    <FastPolarityEnabled>False</FastPolarityEnabled>
    <MS1CentroidDataAbsThreshold>200</MS1CentroidDataAbsThreshold>
    <MS1CentroidDataRELThreshold>0.010</MS1CentroidDataRELThreshold>
    <MS2CentroidDataAbsThreshold>5</MS2CentroidDataAbsThreshold>
    <MS2CentroidDataRELThreshold>0.010</MS2CentroidDataRELThreshold>
    <TimeSegment>
      <Index>1</Index>
      <StartTime>0.0</StartTime>
      <DivertValveState>MS</DivertValveState>
      <StorageMode>Profile</StorageMode>
      <IonMode>ESI</IonMode>
      <TimeSourceParameter>
        <Id>DGasHeater</Id>
        <Value>300</Value>
      </TimeSourceParameter>
      <TimeSourceParameter>
        <Id>DGasFlow</Id>
        <Value>10.0</Value>
      </TimeSourceParameter>
      <TimeSourceParameter>
        <Id>NebulizerPressure</Id>
        <Value>7</Value>
      </TimeSourceParameter>
      <ScanSegment>
        <Index>1</Index>
        <ionPolarity>Positive</ionPolarity>
        <ScanSourceParameter>
          <Id>VCap</Id>
          <Value>4000</Value>
        </ScanSourceParameter>
        <ScanInstParameter>
          <Id>Fragmentor</Id>
          <Value>75</Value>
        </ScanInstParameter>
        <ScanInstParameter>
          <Id>Skimmer1</Id>
          <Value>50.0</Value>
        </ScanInstParameter>
        <ScanInstParameter>
          <Id>OctopoleRFPeak</Id>
          <Value>125</Value>
        </ScanInstParameter>
      </ScanSegment>
      <Acquisition>
        <AcqMode>MS1</AcqMode>
        <AcqMS1>
          <MinRange>100</MinRange>
          <MaxRange>3000</MaxRange>
          <ScanRate>1.1</ScanRate>
        </AcqMS1>
      </Acquisition>
    </TimeSegment>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>Leu,lle</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>15</OffsetOrMin>
      <YRangeOrMax>100000</YRangeOrMax>
      <EICRange>132.05</EICRange>
      <EICRange>132.15</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>Glycerol</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>10</OffsetOrMin>
      <YRangeOrMax>10000</YRangeOrMax>
      <EICRange>93.00</EICRange>
      <EICRange>93.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>Taurine</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>15</OffsetOrMin>
      <YRangeOrMax>3000</YRangeOrMax>
      <EICRange>126.00</EICRange>
      <EICRange>126.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>TIC</TypeName>
      <Label>TIC</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>80</OffsetOrMin>
      <YRangeOrMax>7000000</YRangeOrMax>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>3AP</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>5</OffsetOrMin>
      <YRangeOrMax>700000</YRangeOrMax>
      <EICRange>87.00</EICRange>
      <EICRange>87.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>IS1</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>20</OffsetOrMin>
      <YRangeOrMax>300000</YRangeOrMax>
      <EICRange>182.00</EICRange>
      <EICRange>182.10</EICRange>
    </Chromatogram>
    <RefMassParameters>
      <EnableRefMassCorrection>Enabled</EnableRefMassCorrection>
      <UseBottleA>False</UseBottleA>
      <RefNebulizer>0</RefNebulizer>
      <AutoRecalibration>
        <AverageScans>11</AverageScans>
        <DetectionWindow>500</DetectionWindow>
        <MinHeight>500</MinHeight>
      </AutoRecalibration>
      <RefMass>66.06306100</RefMass>
      <RefMass>622.02896300</RefMass>
    </RefMassParameters>
  </QTOF>
</AcqMethod>