<CEMethod xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" ModuleType="G7150A" schemaVersion="1.0.4" schemaSI="0" ModuleOptions="">
  <ConfigurationXml>&lt;CEConfig xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" schemaVersion="1.0.2" schemaSI="0"&gt;&lt;DisplayName&gt;CE&lt;/DisplayName&gt;&lt;SerialNumber&gt;DEDAD01557&lt;/SerialNumber&gt;&lt;ModuleType&gt;G7150A&lt;/ModuleType&gt;&lt;ModuleDisplayType&gt;G7150A&lt;/ModuleDisplayType&gt;&lt;ConnectionInfo&gt;&lt;ConnectionType&gt;ConnectionType_IPAddress&lt;/ConnectionType&gt;&lt;IPAddress&gt;192.168.254.11&lt;/IPAddress&gt;&lt;/ConnectionInfo&gt;&lt;FirmwareRevision&gt;B.07.22 [0001]&lt;/FirmwareRevision&gt;&lt;IsExternalPressureInstalled&gt;false&lt;/IsExternalPressureInstalled&gt;&lt;IsMSInstalled&gt;true&lt;/IsMSInstalled&gt;&lt;CEMode&gt;CE&lt;/CEMode&gt;&lt;PressureUnit&gt;Bar&lt;/PressureUnit&gt;&lt;EnableAnalysisWithTemperatureOutOfRange&gt;true&lt;/EnableAnalysisWithTemperatureOutOfRange&gt;&lt;AnalogInputSignalConfiguration&gt;&lt;Enabled&gt;false&lt;/Enabled&gt;&lt;/AnalogInputSignalConfiguration&gt;&lt;/CEConfig&gt;</ConfigurationXml>
  <Timetable />
  <StopTime>
    <StopTimeMode>StopTime_Set</StopTimeMode>
    <StopTimeValue>27</StopTimeValue>
  </StopTime>
  <PostTime>
    <PostTimeMode>PostTime_Off</PostTimeMode>
  </PostTime>
  <LiftOffset>4</LiftOffset>
  <CassetteTemperature>
    <CassetteTemperatureMode>TemperatureSet</CassetteTemperatureMode>
    <TemperatureValue>20</TemperatureValue>
  </CassetteTemperature>
  <Pressure>
    <PressureMode>Off</PressureMode>
  </Pressure>
  <InletVial>
    <Vialnumber>-12</Vialnumber>
  </InletVial>
  <OutletVial>
    <Vialnumber>-2</Vialnumber>
  </OutletVial>
  <ReplenishExecutionMode>Serial</ReplenishExecutionMode>
  <UseElectric>true</UseElectric>
  <Power>
    <PowerValue>5</PowerValue>
  </Power>
  <Voltage>
    <VoltageValue>-30</VoltageValue>
  </Voltage>
  <Current>
    <CurrentValue>50</CurrentValue>
  </Current>
  <CurrentLowerLimitAlarm>
    <CurrentLowerLimitAlarmMode>LimitSet</CurrentLowerLimitAlarmMode>
    <CurrentLowerLimitValue>5</CurrentLowerLimitValue>
  </CurrentLowerLimitAlarm>
  <ReplenishProgram />
  <PreconditioningProgram>
    <ProgramInstructions xsi:type="ProgramInstructionFlushType" ObjectID="be844ef5-7758-4aae-8ba7-637022f939dc">
      <Duration>120</Duration>
      <InletVial>
        <Vialnumber>-14</Vialnumber>
      </InletVial>
      <OutletVial>
        <Vialnumber>-2</Vialnumber>
      </OutletVial>
    </ProgramInstructions>
    <ProgramInstructions xsi:type="ProgramInstructionFlushType" ObjectID="fcfd347b-e2b4-4d9a-915d-a21daa071d57">
      <Duration>300</Duration>
      <InletVial>
        <Vialnumber>-13</Vialnumber>
      </InletVial>
      <OutletVial>
        <Vialnumber>-2</Vialnumber>
      </OutletVial>
    </ProgramInstructions>
  </PreconditioningProgram>
  <InjectionProgram>
    <ProgramInstructions xsi:type="ProgramInstructionApplyPressureType" ObjectID="4a838d40-3639-4ce5-9502-50031add89ad">
      <Duration>30</Duration>
      <Pressure>50</Pressure>
      <InletVial>
        <Vialnumber>-1</Vialnumber>
      </InletVial>
      <OutletVial>
        <Vialnumber>-2</Vialnumber>
      </OutletVial>
    </ProgramInstructions>
    <ProgramInstructions xsi:type="ProgramInstructionApplyPressureType" ObjectID="2273ef13-57a8-4a0e-95fe-b22d7419d83f">
      <Duration>4</Duration>
      <Pressure>50</Pressure>
      <InletVial>
        <Vialnumber>-3</Vialnumber>
      </InletVial>
      <OutletVial>
        <Vialnumber>-2</Vialnumber>
      </OutletVial>
    </ProgramInstructions>
  </InjectionProgram>
  <PostconditioningProgram />
</CEMethod>