MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS235 Study Title Analysis of unripe papaya Study Description In this study, we analyzed fruit of unripe papaya to reveal the functionalities. Samples were analyzed using LC/Q-TOF. Experimental Design sex design Experimental Factor Name sex tissue Experimental Factor Type sex tissue Person Last Name Kera Hideyuki Person First Name Kota Suzuki Person Mid Initials Person Affiliation Department of Nutritional Science and Food Safty, Tokyo University of Agriculture Kazusa DNA Research Institute Person Roles submitter submitter PubMed ID 39463775 Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Description Four hermaphrodites and female unripe papaya fruits were obtained from Yaginuma Farm Co., Ltd. (Ibaraki, Japan) in mid-October 2021. They were separated into peel, pulp, and seed, and stored at -80 °C until use. The stored samples were lyophilized and powdered using a milser (IFM-800DGM; Iwatani Corporation, Osaka, Japan). The powder (10 mg) was mixed with 500 µL of 80% methanol, centrifuged at 15000 min-1 for 10 min, and filtered using a Mono-Spin C18 column (GL Science Inc., Tokyo, Japan). The eluted solutions were filtered through a 0.2 µm polytetrafluoroethylene (PTFE) membrane. Samples were analyzed by Agilent 1260 Infinity LC system with Agilent 1260 Infinity Diode Array Detector VL+. Samples were injected by Agilent 1260 HiP ALS Autosampler, and separated using the InertSustain AQ-C18 column (column size: 2.1 × 150 mm; particle size: 3.0 µm; GL Science Inc.). Mobile phases A (0.1% formic acid in water) and B (0.1% formic acid in acetonitrile) were used with a gradient of 2% B for 0-3 min, 2-98% B for 3-30 min, 98% B for 30-35 min, and 2% B for 35-40 min. Column temperature and flow rate were maintained at 40 °C and 200 µL/min, respectively. Samples were analyzed by LC/Q-TOF (Agilent 6530 Accurate Mass Q-TOF, Agilent Technologies, Inc., CA, USA). Mass spectrometry analysis was performed in electrospray ionization positive mode, covering a mass range from m/z 50 to 1500 for full mass scans and m/z 25 to 1500 for the targeted MS/MS scans. Processed data not submitted. Metabolite assignment data not submitted. Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution;Temperature Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Protocol Software Public Release Date 2025-07-04 Term Source Name Term Source File Term Source Version SDRF File MTBKS235.sdrf.txt Comment[Study type] metabolomics Comment[Experiment type] liquid chromatography-mass spectrometry Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB17161 Comment[Related study] Comment[Contributor] Comment[Submission Date] 2024-01-15 Comment[Last Update Date] 2025-07-04