MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS256 Study Title Role of lysosomes in therapeutic resistance in glioblastoma cells Study Description To gain insights into the specific metabolic regulation associated with lysosomal activity, we endeavored to identify differences between groups of GBM cell lines with high and low lysosomal activity through metabolome analysis. Experimental Design strain or line design Experimental Factor Name phenotype cell_line Experimental Factor Type phenotype cell_line Person Last Name Kobayashi Person First Name Masahiko Person Mid Initials Person Affiliation Kanazawa University, Cancer Research Institute Person Roles submitter PubMed ID Publication DOI Protocol Name Sample collection Extraction Capillary Electrophoresis 1 Capillary Electrophoresis 2 Mass spectrometry 1 Mass spectrometry 2 Data processing Metabolite identification Protocol Type Sample collection Extraction Capillary Electrophoresis Capillary Electrophoresis Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description "Cell culture: Patient-derived glioblastoma (GBM) cell lines were cultured as spheroids on an ultra-low attachment culture plate in neural stem progenitor cell (NSPC) medium, which contained DMEM/F12, B27, 5% penicillin/streptomycin, hEGF (20 ng/mL), and hFGF (20 ng/mL) at 37 °C in a humidified atmosphere of 5% CO2 and 5% oxygen. Sample preparation: Cultured cells were passaged into fresh NSPC medium. Next day, spheroids were collected." The cells were dissociated with accutase and washed with 5% mannitol and lysed with methanol (1 mL) containing 25 μM internal standards (L-methionine sulfone, 2-morpholinoethanesulfonic acid, monohydrate (MES), D-camphor-10-sulfonic acid sodium salt (CSA), and homogenized. The sample (400 μL) was transferred to a fresh tube, and 400 μL of chloroform and 200 μL of Milli-Q water were added. The mixture was centrifuged at 10,000 x g for 3 min at 4 °C, and 400 μL of the upper aqueous layer was centrifugally filtered through a 5-kDa cut-off filter to remove proteins. The filtered samples (320 μL) were lyophilized and dissolved in 25 μL of Milli-Q water containing 200 μM reference compounds (3-aminopyrrolidine and trimesate). All capillary electrophoresis time-of-flight mass spectrometry (CE-TOFMS) experiments were performed using an Agilent CE capillary electrophoresis system, an Agilent G6230B LC/MSD TOF system, an Agilent1260 Infinity 2 series binary HPLC pump, and the G1603A Agilent CE-MS adapter- and G1607A Agilent CE-ESI-MS sprayer kit. For system control and data acquisition we used the MassHunter workstation software version B.08.00 for Agilent CE-TOFMS. To analyze cationic compounds, a fused silica capillary (50 µm i.d. × 100 cm) was used with 1 M formic acid as the electrolyte. Approximately 5 nl of sample solution were injected at 50 mbar for 5 s and 30kV of voltage was applied. The capillary temperature was maintained at 20°C and the sample tray was cooled below 5°C. Methanol/water (50% v/v) containing 0.01 µM hexakis(2,2-difluoroethoxy)phosphazene was delivered as the sheath liquid at 10 µL/min. All capillary electrophoresis time-of-flight mass spectrometry (CE-TOFMS) experiments were performed using an Agilent CE capillary electrophoresis system, an Agilent G6230B LC/MSD TOF system, an Agilent1260 Infinity 2 series binary HPLC pump, and the G1603A Agilent CE-MS adapter- and G1607A Agilent CE-ESI-MS sprayer kit. For system control and data acquisition we used the MassHunter workstation software version B.08.00 for Agilent CE-TOFMS. To analyze anionic metabolites, a commercially available COSMO(+) (chemically coated with cationic polymer) capillary (50 µm i.d. x 105 cm) was used with a 50 mM ammonium acetate solution (pH 8.5) as the electrolyte. Sample solution (30 nl) was injected at 50 mbar for 30 s and -30kV of voltage was applied. Methanol/5 mM ammonium acetate (50% v/v) containing 0.01 µM hexakis(2,2-difluoroethoxy)phosphazene was delivered as the sheath liquid at 10 µL/min. Platinum needle was used for anionic metabolite analysis. For cationic compounds, ESI-TOFMS was performed in positive ion mode, and the capillary voltage was set to 4 kV. A flow rate of heated dry nitrogen gas (heater temperature 300°C) was maintained at 7 psig. In TOFMS, the fragmentor, skimmer, and Oct RFV voltage were set at 75V, 50V, and 500V, respectively. Automatic recalibration of each acquired spectrum was achieved using the masses of the reference standards (13C isotopic ion of a protonated methanol dimer, m/z 66.0631) and (protonated ion of hexakis(2,2-difluoroethoxy)phosphazene, m/z 622.0290). For anionic metabolites, ESI-TOFMS was performed in negative ion mode, and the capillary voltage was set to 3.5 kV. For TOFMS, the fragmentor, skimmer, and Oct RFV voltage were set at 100V, 50V, and 500V, respectively. Automatic recalibration of each acquired spectrum was performed using reference masses of standards, i.e., (13C isotopic ion of deprotonated acetatic acid dimer, m/z 120.0383) and ([hexakis(2,2-difluoroethoxy)phosphazene + deprotonated acetic acid, m/z 680.0355). CE-TOFMS raw data were analyzed using our proprietary software MasterHands (ver, 2.17.0.10). Briefly, the data processing for each experiment included data conversion, binning data into 0.02 m/z slices, baseline elimination, peak picking, integration, and elimination of redundant features to yield the all possible peaks lists. Data matrices were generated by an alignment process based on corrected migration times, and metabolite names were assigned to the aligned peaks by matching m/z and the corrected migration times of our standards library. Relative peak areas were calculated based on the ratio of peak area divided by those of internal standards, and metabolite concentrations were calculated based on the relative peak area between the sample and standard mixture. To identify metabolites, relative migration times of all peaks were calculated by normalization to the reference compound 3-aminopyrrolidine. The metabolites were identified by comparing their m/z values and relative migration times to the metabolite standards. Quantification was performed by comparing peak areas to calibration curves generated using internal standardization techniques with methionine sulfone. The other conditions were identical to those described previously (doi: 10.1074/jbc.M601876200.). For anion analysis, trimesate and CAS were used as the reference and the internal standards, respectively. The other conditions were identical to those described previously (doi: 10.1021/ac900675k.). Protocol Parameters Post extraction;Derivatization CE instrument;Autosampler model;Column model;Column type CE instrument;Autosampler model;Column model;Column type Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Protocol Software Public Release Date 2024-12-26 Term Source Name Term Source File Term Source Version SDRF File MTBKS256.sdrf.txt Comment[Study type] metabolite profiling Comment[Experiment type] capillary electrophoresis-mass spectrometry Comment[Submission type] CE-MS Comment[BioProject] PRJDB19721 Comment[Related study] Comment[Contributor] Comment[Submission Date] 2024-12-24 Comment[Last Update Date] 2024-12-26