﻿<?xml version="1.0" encoding="utf-8"?>
<AcqMethod>
  <Version>1.0</Version>
  <!--Method Properties-->
  <MethodName>Anion_Neb7.m</MethodName>
  <MethodPath>D:\MassHunter\Data\TOF9\keiko.k\230327_A_FUKUDA-333(fukuda-162)\13_d4.d\AcqData\Anion_Neb7.m</MethodPath>
  <MethodDescription>Default Method</MethodDescription>
  <!--List of Devices-->
  <DeviceList>MS TOF</DeviceList>
  <!--Device Specific Setpoints-->
  <QTOF>
    <ComponentModel>G6210A</ComponentModel>
    <ComponentName>MS TOF</ComponentName>
    <IonSource>Dual ESI</IonSource>
    <TuneFile>AutoTune.tun</TuneFile>
    <StopMode>NoLimit</StopMode>
    <StopTime>30.00</StopTime>
    <NoWaitForTemp>Enable</NoWaitForTemp>
    <FastPolarityEnabled>False</FastPolarityEnabled>
    <MS1CentroidDataAbsThreshold>200</MS1CentroidDataAbsThreshold>
    <MS1CentroidDataRELThreshold>0.010</MS1CentroidDataRELThreshold>
    <MS2CentroidDataAbsThreshold>5</MS2CentroidDataAbsThreshold>
    <MS2CentroidDataRELThreshold>0.010</MS2CentroidDataRELThreshold>
    <TimeSegment>
      <Index>1</Index>
      <StartTime>0.0</StartTime>
      <DivertValveState>MS</DivertValveState>
      <StorageMode>Profile</StorageMode>
      <IonMode>ESI</IonMode>
      <TimeSourceParameter>
        <Id>DGasHeater</Id>
        <Value>300</Value>
      </TimeSourceParameter>
      <TimeSourceParameter>
        <Id>DGasFlow</Id>
        <Value>10.0</Value>
      </TimeSourceParameter>
      <TimeSourceParameter>
        <Id>NebulizerPressure</Id>
        <Value>7</Value>
      </TimeSourceParameter>
      <ScanSegment>
        <Index>1</Index>
        <ionPolarity>Negative</ionPolarity>
        <ScanSourceParameter>
          <Id>VCap</Id>
          <Value>3500</Value>
        </ScanSourceParameter>
        <ScanInstParameter>
          <Id>Fragmentor</Id>
          <Value>100</Value>
        </ScanInstParameter>
        <ScanInstParameter>
          <Id>Skimmer1</Id>
          <Value>50.0</Value>
        </ScanInstParameter>
        <ScanInstParameter>
          <Id>OctopoleRFPeak</Id>
          <Value>200</Value>
        </ScanInstParameter>
      </ScanSegment>
      <Acquisition>
        <AcqMode>MS1</AcqMode>
        <AcqMS1>
          <MinRange>100</MinRange>
          <MaxRange>3000</MaxRange>
          <ScanRate>1.1</ScanRate>
        </AcqMS1>
      </Acquisition>
    </TimeSegment>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>CSA</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>15</OffsetOrMin>
      <YRangeOrMax>600000</YRangeOrMax>
      <EICRange>231.00</EICRange>
      <EICRange>231.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>Trimesate</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>20</OffsetOrMin>
      <YRangeOrMax>1000000</YRangeOrMax>
      <EICRange>209.00</EICRange>
      <EICRange>209.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>3peaks</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>25</OffsetOrMin>
      <YRangeOrMax>100000</YRangeOrMax>
      <EICRange>259.00</EICRange>
      <EICRange>259.20</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>NAD</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>40</OffsetOrMin>
      <YRangeOrMax>10000</YRangeOrMax>
      <EICRange>662.00</EICRange>
      <EICRange>662.10</EICRange>
    </Chromatogram>
    <Chromatogram>
      <TypeName>TIC</TypeName>
      <Label>TIC</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>80</OffsetOrMin>
      <YRangeOrMax>25000000</YRangeOrMax>
    </Chromatogram>
    <Chromatogram>
      <TypeName>EIC</TypeName>
      <Label>DCA</Label>
      <ExperimentType>MS</ExperimentType>
      <ActualOrSetpointType />
      <OffsetOrMin>50</OffsetOrMin>
      <YRangeOrMax>10000000</YRangeOrMax>
      <EICRange>391.00</EICRange>
      <EICRange>392.00</EICRange>
    </Chromatogram>
    <RefMassParameters>
      <EnableRefMassCorrection>Enabled</EnableRefMassCorrection>
      <UseBottleA>False</UseBottleA>
      <RefNebulizer>0</RefNebulizer>
      <AutoRecalibration>
        <AverageScans>11</AverageScans>
        <DetectionWindow>500</DetectionWindow>
        <MinHeight>500</MinHeight>
      </AutoRecalibration>
      <RefMass>120.03833900</RefMass>
      <RefMass>680.03554100</RefMass>
    </RefMassParameters>
  </QTOF>
</AcqMethod>