MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS287 Study Title Metabolome analysis of mouse plasma in aging and dietary interventions Study Description This study aims to investigate alterations in metabolites associated with aging and diet. To this end, we performed targeted metabolome analysis using plasma collected from young and aged mice, as well as mice fed either a normal or high-fat diet. Experimental Design stimulus or stress design Experimental Factor Name age diet Experimental Factor Type age diet Person Last Name Tadokoro Person First Name Yuko Person Mid Initials Person Affiliation Cancer Research Institute, Kanazawa University Person Roles submitter PubMed ID Publication DOI Protocol Name Sample collection Extraction Capillary Electrophoresis Mass spectrometry Data processing Metabolite identification Protocol Type Sample collection Extraction Capillary Electrophoresis Mass spectrometry Data processing Metabolite identification Protocol Description Plasma samples from wild-type mice fed a normal diet or a hight-fat diet for 2 months, as well as mice aged 7-16 weeks or >100 weeks, were used. In these plasma samples, 237 anionic and 272 cationic metabolites were quantified by capillary electrophoresis time-of-flight mass spectrometry. Mouse plasma samples (20 µL) were mixed with 20 µL of Milli-Q water and 360 µL of methanol (FUJIFILM Wako Pure Chemical Corporation; Cat. No. 134-14523) containing 20 μM internal standards (ISs): methionine sulfone (Thermo Fisher Scientific Inc, Waltham, MA, USA; A17027), D-camphor-10-sulfonic acid (FUJIFILM Wako Pure Chemical Corporation; Cat. No. 037-01032), and MES (FUJIFILM Wako Pure Chemical Corporation; Cat. No. 341-01622), followed by the addition of 400 µL of chloroform and 160 µL of Milli-Q water, vortexing, and centrifugation at 10,000 × g for 3 min at 4°C. The upper aqueous layer (300 µL) was collected and filtered using a 5-kDa cutoff filter (Human Metabolome Technologies, Tsuruoka, Japan) at 9,100 × g for 3 h at 20°C. The filtrate was concentrated by centrifugal evaporation for 2 h at 40°C and reconstituted in 25 µL of Milli-Q water containing 200 μM ISs (3-aminopyrrolidine [Sigma-Aldrich; Cat. No. 404624] and trimesic acid [FUJIFILM Wako Pure Chemical Corporation; Cat. No. 206-03641]) for capillary electrophoresis-time-of-flight mass spectrometry (CE-TOFMS) analysis. "Metabolite concentrations were measured using a CE-TOFMS system (Agilent Technologies, Waldbronn, Germany). For anionic metabolite analysis, a COSMO(+)Capillary (50 μm internal diameter × 105 cm; Nacalai Tesque, Kyoto, Japan) was used with 50 mM ammonium acetate (pH 8.5) (FUJIFILM Wako Pure Chemical Corporation; Cat. No. 019-02835) as the running electrolyte. Samples (30 nL) were injected at 50 mbar for 30 s, and separation was performed under an applied voltage of -30 kV at 20°C. For cationic metabolite analysis, a fused silica capillary (50 µm internal diameter × 100 cm) with 1 M formic acid (FUJIFILM Wako Pure Chemical Corporation; Cat. No. 063-05895) as the electrolyte was used. Samples (5 µL) were injected at 50 mbar for 5 s, and separation was carried out at 30 kV and 20°C." "For anionic metabolite analysis, the sheath liquid consisted of 5 mM ammonium acetate in 50% (v/v) methanol/water containing 0.01 μM hexakis(2,2-difluoroethoxy)phosphazene (SynQuest Laboratories, Alachua, FL, USA; Cat. No. 8H79-3-02), delivered at 10 μL/min. Electrospray ionization (ESI) was conducted in negative ion mode with a capillary voltage of 3.5 kV. The fragmentor, skimmer, and OCT RFV voltages were set to 100, 50, and 500 V, respectively. Mass spectra were automatically recalibrated using reference ions: the 13C isotopic ion of the deprotonated acetic acid dimer (m/z 120.038339) and the adduct of hexakis(2,2-difluoroethoxy)phosphazene with deprotonated acetic acid (m/z 680.035541). For cationic metabolite analysis, the sheath liquid was 50% (v/v) methanol/water containing 0.01 μM hexakis(2,2-difluoroethoxy)phosphazene, delivered at 10 μL/min. ESI was performed in positive ion mode with a capillary voltage of 4 kV and a heated nitrogen gas flow (10 L/min at 300°C). The fragmentor, skimmer, and OCT RFV voltages were set to 75, 50, and 500 V, respectively. Mass spectra were recalibrated using reference ions: the 13C isotopic ion of the protonated methanol dimer (m/z 66.063061) and the protonated ion of hexakis(2,2-difluoroethoxy)phosphazene (m/z 622.028963)." Data analysis was carried out using MasterHands (ver. 2.17.3.17; Keio University, Tsuruoka, Japan) and MetaboAnalyst 6.0 (Sugimoto et al., 2010). To identify metabolites, relative migration times of all peaks were calculated by normalization to the reference compound 3-aminopyrrolidine. The metabolites were identified by comparing their m/z values and relative migration times to the metabolite standards. Quantification was performed by comparing peak areas to calibration curves generated using internal standardization techniques with methionine sulfone. The other conditions were identical to those described previously (doi: 10.1074/jbc.M601876200.). For anion analysis, trimesate and CAS were used as the reference and the internal standards, respectively. The other conditions were identical to those described previously (doi: 10.1021/ac900675k.). Protocol Parameters Post extraction;Derivatization CE instrument;Autosampler model;Column model;Column type Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Protocol Software Public Release Date 2026-10-02 Term Source Name Term Source File Term Source Version SDRF File MTBKS287.sdrf.txt Comment[Study type] metabolite profiling Comment[Experiment type] capillary electrophoresis-mass spectrometry Comment[Submission type] CE-MS Comment[BioProject] PRJDB45654 Comment[Related study] Comment[Contributor] Comment[Submission Date] 2026-09-15 Comment[Last Update Date] 2026-10-02