Parameters for F:\180821.PRO\ACQUDB\180821_705_24N_001.EXP Data Processing: SIR / MRM Chromatogram Spike Removal ON SIR / MRM Smoothing OFF Smoothing window size (scans) 3 Number of smooths 2 Prescan Statistics: Initial Average Intensity 14.3606 Initial Average Std Dev 1.2799 Bunch Zero Level 0.0000 Bunch Std Dev 0.0000 Bunch Threshold 0.0000 Spike Removal Std Dev 1.1564 Method Events: Initial Stop Flow: No Change Initial Switch 2: No Change Initial Switch 3: No Change Initial Switch 4: No Change Initial Infusion: No Change Initial Flow State: LC Initial Flow Rate: 5 Initial Reservoir: No Action API Probe Delay Temp: 1 Initial Refill: No Action Timed Events Disabled Event Time(Sec) Name Action Source Information: Type - ESI Status - Option Connector Disconnected ScanWave Optimisation File: ScanWave File is not loaded Ion Count Threshold: 25.0000 Ion Count Threshold (adjusted for gain): 25.0000 Instrument Parameters - Function 1: Parameter File - F:\180821.PRO\ACQUDB\sawada2013.IPR Polarity ES- Calibration Static 2 Capillary (kV) 0.80 0.94 Cone (V) 50.00 -144.18 Source Offset (V) 50.0 Source Temperature (°C) 150 150 Desolvation Temperature (°C) 600 600 Cone Gas Flow (L/Hr) 150 145 Desolvation Gas Flow (L/Hr) 1000 990 Collision Gas Flow (mL/Min) 0.20 0.19 Nebuliser Gas Flow (Bar) 7.00 6.35 LM 1 Resolution 3.2 HM 1 Resolution 14.5 Ion Energy 1 0.8 MS Mode Collision Energy 4.00 MSMS Mode Collision Energy 3.00 MS Mode Entrance 1.00 MS Mode Exit 1.00 Gas On MS Mode Entrance 1.00 Gas On MS Mode Exit 1.00 Gas On MSMS Mode Entrance 1.00 Gas On MSMS Mode Exit 1.00 Gas Off MS Mode Entrance 1.00 Gas Off MS Mode Exit 1.00 Gas Off MSMS Mode Entrance 30.00 Gas Off MSMS Mode Exit 30.00 ScanWave MS Mode Entrance 1.00 ScanWave MS Mode Exit 1.00 ScanWave MSMS Mode Entrance 1.00 ScanWave MSMS Mode Exit 1.00 LM 2 Resolution 3.2 HM 2 Resolution 14.7 Ion Energy 2 1.5 Gain 1.00 Multiplier 541.39 Active Reservoir Wash Instrument Parameters - Function 2: Parameter File - F:\180821.PRO\ACQUDB\sawada2013.IPR Polarity ES- Calibration Static 2 Capillary (kV) 0.80 0.94 Cone (V) 50.00 -144.18 Source Offset (V) 50.0 Source Temperature (°C) 150 150 Desolvation Temperature (°C) 600 600 Cone Gas Flow (L/Hr) 150 145 Desolvation Gas Flow (L/Hr) 1000 990 Collision Gas Flow (mL/Min) 0.20 0.19 Nebuliser Gas Flow (Bar) 7.00 6.35 LM 1 Resolution 3.2 HM 1 Resolution 14.5 Ion Energy 1 0.8 MS Mode Collision Energy 4.00 MSMS Mode Collision Energy 3.00 MS Mode Entrance 1.00 MS Mode Exit 1.00 Gas On MS Mode Entrance 1.00 Gas On MS Mode Exit 1.00 Gas On MSMS Mode Entrance 1.00 Gas On MSMS Mode Exit 1.00 Gas Off MS Mode Entrance 1.00 Gas Off MS Mode Exit 1.00 Gas Off MSMS Mode Entrance 30.00 Gas Off MSMS Mode Exit 30.00 ScanWave MS Mode Entrance 1.00 ScanWave MS Mode Exit 1.00 ScanWave MSMS Mode Entrance 1.00 ScanWave MSMS Mode Exit 1.00 LM 2 Resolution 3.2 HM 2 Resolution 14.7 Ion Energy 2 1.5 Gain 1.00 Multiplier 541.39 Active Reservoir Wash Engineers Settings: MS1 Low Mass Position 671 MS1 High Mass Position 290 MS1 Low Mass Resolution 217 MS1 High Mass Resolution 1931 MS1 Resolution Linearity 531 MS1 High Mass DC Balance -0.20 MS1 DC Polarity Positive MS2 Low Mass Position 670 MS2 High Mass Position 291 MS2 Low Mass Resolution 216 MS2 High Mass Resolution 1788 MS2 Resolution Linearity 537 MS2 High Mass DC Balance 0.10 MS2 DC Polarity Negative Inter-scan delays: Automatic Mode MS Inter-scan delay (secs) 0.003 Polarity/Mode switch Inter-scan delay (secs) 0.020 Enhanced Inter-scan delay (secs) 0.020 Inter-channel delay - See Tables MS 1 Delay Table: R delay <=-1800.000 0.006 <=-1500.000 0.005 <=-1000.000 0.004 <=1000.000 0.003 <=1500.000 0.004 <=1800.000 0.005 > 1800.000 0.006 RF 2 Delay Table: R delay <=-150.000 0.006 <= -75.000 0.005 <= -10.000 0.004 <= 10.000 0.003 <= 20.000 0.004 <= 40.000 0.005 <= 70.000 0.006 <= 100.000 0.007 <= 150.000 0.008 <= 200.000 0.009 <= 250.000 0.010 <= 275.000 0.011 > 275.000 0.012