MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS62 Study Title Chlamydomonas reinhardtii metabolite analysis Study Description Investigation of green algae Chlamydomonas reinhardtii C-9 metabolites. 3 replicates data are examined. Experimental Design species design Experimental Factor Name Experimental Factor Type Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Description Chlamydomonas reinhardtii C-9 mt- are grown in the TAP culture medium in an incubator (150rpm). The strain is provided from Dr Hideya Fukuzawa, Kyoto Univ. Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 500 microL 80% methanol solution. Cells are homogenized by TissueLyser (QUIAGEN) and centrifuged (15000rpm, 10min, 4 degree C). 20 microL of the supernatant (300 microL) is injected into HPLC after 0.2 micrometre membrane filter treatment. Instrument: Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: Elute monitoring by PDA equipped with Agilent 1200 LC (Agilent Technologies) in 2 nm step.; Max wave length for elute monitering: 600.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSKgel Amide-80 (4.6 x 250 mm, 5 micrometer; TOSOH); Column temperature: 40.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B);80 to 45% (0.0 to 30.0 min), 45 to 35% (30.0 to 30.1 min), 35% (30.1 to 35.0 min), 35% to 80% (35.0 to 35.1 min), 80% (35.1 to 42.0 min); Flow rate: 0.8 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.) Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Xcalibur scan setting: Filter 1: FTMS + c norm !corona !pi res=60000 o(150.0-2000.0); 2: FTMS + c norm !corona !pi res=7500 Dep MS/MS Most intense ion from (1); 3: FTMS + c norm !corona !pi res=7500 Dep MS/MS 2nd most intense ion from (1).; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resolution: 60000; Scan mass range: m/z 150.0-2000.0 Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); PowerGet analysis for detection of all peaks : Raw data files are converted to text file by MSGet software without cut off value and peaks are extracted from the text files by PowerFT with parameters (intensity cut off in peak detection=20000, margin of ion grouping in peak detection=5, peak selection filter is default, intensity cut off in peak assignment=1000). In annotation process, KEGG, KNApSAcK and LipidMAPS are used for primary database search. Peaks with no hit to these databases are then selected to secondary search using exactMassDB and Pep1000 databases. After the database search processes, each database hits are manually checked to assign a compound name or compound category name. In case of no compound name or compound category name can assign, predicted molecular formulas are used for the annotation. Peaks without predicted molecular formula are assigned as "unidentified" peak. Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer Protocol Software Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); PowerGet(Sakurai et al., BioMed Research International, 2014:194812) PowerGet(Sakurai et al., BioMed Research International, 2014:194812) Public Release Date 2024-06-14 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS62.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry orbitrap Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14160 Comment[Related study] Metabolonote:SE7 Comment[Contributor] Hideki Nagasaki, Sachiko Osawa, Hideki Hirakawa, Norimoto Shimada, Mitsuo Enomoto, Nozomu Sakurai, Hideyuki Suzuki, Daisuke Shibata (Kazusa DNA Research Institute) Comment[Submission Date] 2019-10-05 Comment[Last Update Date] 2024-06-14