MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS70 Study Title Comparison of fruit metabolites among developmental stages of Jatropha curcas Study Description Investigation of Jatropha curcas fruit metabolites. 4 developmental stages and 3 replicates data are examined. Experimental Design development or differentiation design Experimental Factor Name dev_stage Experimental Factor Type dev_stage Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID Publication DOI DOI: 10.5511/plantbiotechnology.12.0503a Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description Jatropha curcas are grown in an open experimental field at the University of the Ryukyus (Okinawa island, Okinawa, Japan), located in a subtropical area. Methanol [for HPLC Solvent] solution was used for blank sample. Harvested sample is frozen by liquid N2 and ground to powder by a homogenizer, Shake Master (Biomedical Science, Tokyo, Japan). The powdered sample (100mg) are solved in 300 microL 80% methanol solution. 10 microL sample is injected into HPLC after 0.2 micrometre membrane filter treatment. Instrument: Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: Elute monitoring by PDA equipped with Agilent1200 HPLC in 2 nm step.; Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSKgel ODS-100V (4.6 x 250 mm, 5 micrometer; TOSOH); Column temperature: 40.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B);3 to 97% (0.0 to 45.0 min), 97% (45.1 to 50.0 min), 3% (50.1 to 57.0 min); Flow rate: 0.5 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.); Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1)., Rejected mass=102.09000, 102.13000, 103.11000, 116.14000, 121.12000, 130.16000, 158.00000, 171.15000, 202.13000, 235.18000, 249.21000, 252.22000, 294.26000, 308.00000, 376.04000, 379.04000, 380.03000, 540.61000, 540.95000, 609.28000, 810.41000, 1101.70000, 1123.68000, 1146.75000, 1147.76000.; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: LTQ-Orbitrap; Resoluton: 60000; Scan mass range: m/z 100.0-1500.0; Instrument: LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer; MS scan setting: Orbitrap-MS conditions: Filter 1:FTMS - c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS - c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS - c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS - c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS - c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS - c norm !corona !pi Dep MS/MS 5th most intense ion from (1).; Data processing software: Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Negative; Mass analyser: LTQ-Orbitrap; Resoluton: 60000; Scan mass range: m/z 100.0-1500.0; Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); PowerGet analysis for detection of all peaks : Raw data files are converted to text file by MSGet software without cut off value and peaks are extracted from the text files by PowerFT with parameters (intensity cut off in peak detection=30000, margin of ion grouping in peak detection=5, peak selection filter is default). The replicates data are aligned by PowerMatch with blank data. The alignment is manually edited. Assigned peaks observed in multiple replicate samples are selected for annotation process. In annotation process, KEGG, KNApSAcK and LipidMAPS are used for primary database search. Peaks with no hit to these databases are then selected to secondary search using exactMassDB and Pep1000 databases. After the database search processes, each database hits are manually checked to assign a compound name or compound category name. In case of no compound name or compound category name can assign, predicted molecular formulas are used for the annotation. Peaks without predicted molecular formula are assigned as "unidentified" peak. Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1200 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer LTQ-Orbitrap XL (Thermo Fisher Scientific) Hybrid linear ion trap (LTQ)/orbitrap mass spectrometer Protocol Software Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA) Xcalibur 2.0 (Thermo Fisher Scientific, Waltham, MA, USA); PowerGet(Sakurai et al., BioMed Research International, 2014:194812) PowerGet(Sakurai et al., BioMed Research International, 2014:194812) Public Release Date 2020-10-05 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS70.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry orbitrap Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14166 Comment[Related study] Metabolonote:SE15 Comment[Contributor] Hideki Nagasaki 1, Sachiko Osawa 1, Hideki Hirakawa 1, Ryosuke Sano 1, Nayumi Akimoto 1, Yoshihiko Morishita 1, Mitsuo Enomoto 1, Nozomu Sakurai 1, Hideyuki Suzuki 1, Yasunori Fukuzawa 2, Yoshinobu Kawamitsu 2, Masami Ueno 2, Daisuke Shibata 1 (1: Kazusa DNA Research Institute, 2: Faculty of Agriculture, University of the Ryukyus) Comment[Submission Date] 2019-10-05 Comment[Last Update Date] 2024-06-14