MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS81 Study Title Arabidopsis thaliana T87 culture cell metabolite analysis Study Description Investigation of Arabidopsis thaliana T87 culture cell metabolites. 4 replicates data are examined for each sample. Experimental Design species design Experimental Factor Name Experimental Factor Type Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Data processing Metabolite identification Protocol Description Arabidopsis thaliana T87 cells were obtained from the RIKEN BioResource Center (Tsukuba, Japan). Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300 microL 80% methanol solution. 20 microL sample is injected into HPLC after 0.2 micrometre membrane filter treatment. Instrument: Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: Elute monitoring by PDA equipped with Agilent1100 HPLC in 2 nm step.; Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSKgel ODS-100V (4.6 x 250 mm, 5 micrometre; TOSOH); Column temperature: 30.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B);3 to 80% (0.0 to 45.0 min), 80 to 95% (45.0 to 45.1 min), 95% (45.1 to 50.0 min), 3% (50.1 to 57.0 min); Flow rate: 0.5 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.) Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); MS scan setting: FT-ICR-MS conditions: Filter 1: FTMS + c norm !corona !pi res=100000 o(200.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1).; Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Fragmentation method: Collision Induced Dissociation (CID); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resolution: 100000; Scan mass range: m/z 200.0-1500.0 data not submitted data not submitted Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) Protocol Software Xcalibur (Thermo Fisher Scientific K.K) Public Release Date 2020-10-05 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS81.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry fourier transform ion cyclotron resonance mass spectrometry Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14169 Comment[Related study] Metabolonote:SE29 Comment[Contributor] Hideki Nagasaki, Sachiko Osawa, Hideki Hirakawa, Ryosuke Sasaki, Mitsuo Enomoto, Nozomu Sakurai, Hideyuki Suzuki, Daisuke Shibata (Kazusa DNA Research Institute) Comment[Submission Date] 2019-10-05 Comment[Last Update Date] 2024-06-14