MAGE-TAB Version 1.1 Comment[MetaboBank accession] MTBKS93 Study Title Metabolic profiling of flavonoids in Lotus japonicus Study Description Metabolic profiling of flavonoids in leaf, stem, flower of Lotus japonicus Miyakojima MG-20 and Gifu B-129. Experimental Design strain or line design organism part comparison design Experimental Factor Name ecotype tissue Experimental Factor Type ecotype tissue Person Last Name Ara Person First Name Takeshi Person Mid Initials Person Affiliation Kazusa DNA Research Institute Person Roles submitter PubMed ID 17669449 Publication DOI Protocol Name Sample collection Extraction Chromatography Mass spectrometry 1 Mass spectrometry 2 Mass spectrometry 3 Mass spectrometry 4 Data processing Metabolite identification Protocol Type Sample collection Extraction Chromatography Mass spectrometry Mass spectrometry Mass spectrometry Mass spectrometry Data processing Metabolite identification Protocol Description Seed coats of L. japonicus were scratched by glass paper and fed water for 1 day. The seedlings were transferred to a mixture of vermiculite and a commercial soil, Powersoil (mix ratio 1.3-1, Kureha Chemical Ind., Tokyo, Japan, and Kanto Hiryou Ind., Saitama, Japan), and grown for 90-120 days (from March to June) in 2005, in a greenhouse under natural sunlight. From 7-day-old plants, cotyledons and hypocotyls were collected separately and served as leaf and stem samples, respectively. From 14-, 21-, 30-, 60, and 90-day-old plants, leaves and stems were collected. The tissues for one experimental replicate were collected from 12 independent plants for 7-, 14-, and 21-day-old stages, or from one independent plant for 30-, 60-, and 90-day-old stages. Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300 microL 80% methanol solution. 20 microL sample is injected into HPLC after 0.2 micrometre membrane filter treatment. Instrument: Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector; Comment: PDA: 200-650 nm (2 nm step); Max wave length for elute monitering: 650.0 nm; Min wave length for elute monitering: 200.0 nm; Column name: TSKgel ODS-100V (4.6 x 250 mm, 5 micrometre; TOSOH); Column temperature: 30.0 degree C; Elute monitor: photodiode array detector; Flow gradient: Gradient: (B);3 to 42% (0.0 to 45.0 min), 42 to 95% (45.0 to 45.1 min), 95% (45.1 to 50.0 min), 3% (50.1 to 57.0 min); Flow rate: 0.5 ml/min; Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.) Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); MS scan setting: FT-ICR-MS conditions: FT-ICR-MS conditions: Filter 1: FTMS + p norm !corona !pi o(200.0-1500.0);2: ITMS + p norm !corona !pi Dep MS/MS Most intense ion from (1). Rejected mass=249.00;266.00;271.50;294.00;391.00;609.00;810.50;1101.50;1105.50;1123.50;1139.50.; Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Scan mass range: m/z 200.0-1500.0 Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); MS scan setting: FT-ICR-MS conditions: FT-ICR-MS conditions: Filter 1: FTMS + p norm !corona !pi res=100000 o(200.0-1500.0);2: ITMS + p norm !corona !pi Dep MS/MS Most intense ion from (1). Rejected mass=249.00;266.00;271.50;294.00;391.00;609.00;810.50;1101.50;1105.50;1123.50;1139.50.; Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resolution: 100000; Scan mass range: m/z 200.0-1500.0 Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); MS scan setting: FT-ICR-MS conditions: FT-ICR-MS conditions: Filter 1: FTMS + c norm !corona !pi o(200.0-1500.0);2: ITMS + c norm !corona !pi o(200.0-1500.0);3: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (2). Rejected mass=143.00;145.00;171.00;173.00;198.00;199.00;235.00; Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Scan mass range: m/z 200.0-1500.0 Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); MS scan setting: FT-ICR-MS conditions: FT-ICR-MS conditions: Filter 1: 1: FTMS + c norm !corona !pi o(200.0-1500.0)2: FTMS + c norm !corona !pi Dep MS/MS Most intense ion from (1). Rejected mass=249.00;266.00;271.50;294.00;391.00;609.00;810.50;1101.50;1105.50;1123.50;1139.50.; Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Instrument: LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS); Data processing software: Xcalibur (Thermo Fisher Scientific K.K); Ion isolation: ESI; Ion mode: Positive; Mass analyser: FT-ICR; Resolution: Scan mass range: m/z 200.0-1500.0 data not submitted data not submitted Protocol Parameters Post extraction;Derivatization Chromatography instrument;Autosampler model;Column model;Column type;Guard column;Detector;Signal range;Resolution Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Scan polarity;Scan m/z range;Instrument;Ion source;Mass analyzer Protocol Hardware Agilent 1100 HPLC (Agilent Technologies) HPLC equipped with photodiode array detector LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) LTQ-FT (Thermo Fisher Scientific) Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) Protocol Software Xcalibur (Thermo Fisher Scientific K.K) Xcalibur (Thermo Fisher Scientific K.K) Xcalibur (Thermo Fisher Scientific K.K) Xcalibur (Thermo Fisher Scientific K.K) Public Release Date 2020-10-05 Term Source Name Metabolonote Term Source File http://metabolonote.kazusa.or.jp Term Source Version SDRF File MTBKS93.sdrf.txt Comment[Study type] untargeted metabolite profiling Comment[Experiment type] liquid chromatography-mass spectrometry fourier transform ion cyclotron resonance mass spectrometry Comment[Submission type] LC-DAD-MS Comment[BioProject] PRJDB14180 Comment[Related study] Metabolonote:SE42 Comment[Contributor] Hideki Nagasaki 1, Sachiko Osawa 1, Hideki Hirakawa 1, Hideyuki Suzuki 1, Ryosuke Sasaki 1, Yoshiyuki Ogata 1, Yukiko Nakamura 2 4, Nozomu Sakurai 1, Mariko Kitajima 3, Hiromitsu Takayama 3, Shigehiko Kanaya 2, Koh Aoki 1, Daisuke Shibata 1, Kazuki Saito 3 (1: Kazusa DNA Research Institute, 2: Nara Institute of Science and Technology, 3: hiba University, 4: Ehime Women's College) Comment[Submission Date] 2019-10-05 Comment[Last Update Date] 2024-06-14